| Manufacturer part number (MPN) | 5111812 |
| Brand | Fluke |
| Category | Tools |
| Battery Type | 2 AA IEC LR6 alkaline |
| Battery Life | 200 hour |
| Display | Dual readout |
| Automatic Power Off | 20 minutes |
| Range | 999.9 A |
| Resolution | 0.1 A |
| Accuracy | 2 % ±5 digits (45 Hz to 66 Hz) |
| Crest Factor (50/60 Hz) | 3 @ 500 A 2.5 @ 600 A 1.42 @ 1000 A Add 2 % for C.F. >2 |
| Distance from Optimum | i2500-10 Flex |
| A 0.5 in (12.7 mm) | 1.4 in (35.6 mm) |
| B 0.8 in (20.3 mm) | 2.0 in (50.8 mm) |
| C 1.4 in (35.6 mm) | 2.5 in (63.5 mm) |
| Accuracy ≤4/0 AWG | 3 % ±5 digits (45 Hz to 66 Hz) |
| Trigger Level | 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥ 5 A 100 Hz to 500 Hz, ≥ 10 A |
| Size (L x W x H) | 274 mm x 86 mm x 47 mm |
| Weight (with Batteries) | 463 g |
| Jaw Opening | 34 mm |
| Flexible Current Probe Diameter | 7.5 mm |
| Rogowski Coil Length | 450 mm |
| Operating Temperature | -10 °C to 50 °C |
| Storage Temperature | -40 °C to 60 °C |
| Operating Humidity (without condensation) | Non condensing (<10 °C) ≤90 % RH (10 °C to 30 °C) ≤75 % RH (30 °C to 40 °C) ≤45 % RH (40 °C to 50 °C) |
| Temperature Coefficients | Add 0.1 x specified accuracy for each degree C >28 °C or <18 °C |
| Ingress Protection | IEC 60529: IP30 (jaw closed) |
| Operating Altitude | 2000 m |
| Storage Altitude | 12 000 m |
| International | IEC 61326-1: Portable Electromagnetic Environment IEC 61326-2-2 |
| CISPR 11 | Group 1, Class B |
| Korea (KCC) | Class A equipment (Industrial Broadcast & Communications Equipment) |
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
| General | IEC 61010-1: Pollution degree 2 |
| Measurement | IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V |
| Current Clamp for Leakage Current Measurements | IEC 61557-13: Class 2, ≤30 A/m |
| Radio Frequency Certification | FCC ID: T68-FBLE IC:6627A-FBLE |
| Frequency Range | 2405 MHz to 2480 MHz |
| Output Power | <100 mW |