| Manufacturer part number (MPN) | 6162791 |
| Brand | Fluke |
| Category | Tools |
| Maximum voltage between any terminal and earth ground | 1000 V AC 1500 V DC |
| Batteries | 2 AA IEC LR6 alkaline |
| Display | Dual display with backlight |
| Automatic power off | 20 minutes |
| Accuracy | Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]). |
| Temperature coefficients | Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C |
| Range | 999.9 A |
| Resolution | 0.1 A |
| Crest Factor (50/60 Hz) | 2.5 @ 600.0 A 3.0 @ 500.0 A 1.42 @ 999.9 A Add 2 % for C.F. >2 |
| Position sensitivity Distance from Optimum | i2500-10 Flex |
| A 0.5 in (12.7 mm) | 1.4 in (35.6 mm) |
| B 0.8 in (20.3 mm | 2.0 in (50.8 mm |
| C 1.4 in (35.6 mm) | 2.5 in (63.5 mm |
| Voltage | Complies to IEC / EN 61010-031 CAT III 1500 V Do Not Disconnect Under Load Not Intended for Permanent Installation |
| Current | 30 A |
| Temperature Range | +5 °C to +30 °C (+41 °F to +86 °F), < 80 % RH +31 °C to +40 °C (+88 °F to +104 °F), < 50 % RH |