| Manufacturer part number (MPN) | 5593158 |
| Brand | Fluke |
| Category | Tools |
| Function Range | Resolution |
| AC volts[1] 6.000 V | 0.001 V |
| 600.0 V 0.1 V | 2.0 % + 3 (500 Hz to 1 kHz) |
| 1000 V | 1 V |
| DC volts 6.000 V | 0.001 V |
| 1500 V 1 V | 0.15 % + 2 |
| AC mV[1] 600.0 mV | 0.1 mV |
| DC mV 600.0 mV | 0.1 mV |
| Continuity 600 Ω | 1 Ω |
| Resistance 600.0 Ω | 0.1 Ω |
| Resistance 6.000 kΩ | 0.001 kΩ |
| Resistance 6.000 MΩ | 0.001 MΩ |
| 50.00 MΩ 0.01 MΩ | 1.5 % + 4 |
| Capacitance 1000 nF | 1 nF |
| Capacitance 10.00 μF | 0.01 μF |
| 9999 μF 1 μF | 10 % typical |
| Frequency 99.99 Hz | 0.01 Hz |
| Frequency 9.999 kHz | 0.001 kHz |
| AC VA (45 Hz ~ 500 Hz)[1] 360.0 VA | 0.1 VA |
| 3.600 kVA 0.001 kVA | 2 % + 0.01 kVA |
| 36.00 kVA 0.01 kVA | 2 % + 0.1 kVA |
| 60.00 kVA 0.01 kVA | 2 % + 0.15 kVA |
| DC VA[1] 360.0 VA | 0.1 VA |
| 90.00 kVA 0.01 kVA | 2 % + 0.25 kVA |
| Min-max avg | For DC functions, accuracy is the specified accuracy of the measurement function ± 12 counts for changes longer than 350 ms in duration. |
| Operating temperature | -10 °C to 60 °C |
| Storage temperature | -30 °C to +70 °C |
| Humidity (without condensation) | 0 % to 90 %, 10 °C to 30 °C |
| Electromagnetic compatibility | IEC 61326-1, IEC 61326-2-2, Portable, Group 1, Class A |
| Overvoltage category | CAT III 1500 V, CAT IV 1000 V |
| Agency approvals | ETL (AMER and EMEA), CSA (APAC), CE, UK CA |
| Drop test | 2 meter (6.5 ft) drop test |
| Ingress protection | IP52 |
| Warranty | Limited lifetime |
| Counts | 6000 |
| Size | 22.5 cm x 10.5 cm x 5.7 cm (8.8 in x 4.1 in x 2.2 in) |
| Weight | 0.7 kg (1.5 lb) |
| Battery life | > 150 hours typical, without backlight (Alkaline, 3 AA) |