Fluke 1550C FC 5 kV Digital Insulation Tester

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
4977402  ·  HS 9030.33
Fluke 1550C FC 5 kV Digital Insulation Tester

The Fluke 1550C is a megohmmeter insulation resistance tester that offers insulation testing for up to 5 kV; this Fluke insulation tester is ideal for high voltage equipment like switch gear, motors, & cables.

Technical Specifications

Manufacturer part number (MPN)4977402
BrandFluke
CategoryTools
250 V Range50 GΩ
250 V Accuracy (± reading)Unspecified 5% 20% Unspecified
500 V Range100 GΩ
500 V Accuracy (± reading)Unspecified 5% 20% Unspecified
1000 V Range200 GΩ
1000 V Accuracy (± reading)Unspecified 5% 20% Unspecified
2500 V Range500 GΩ
2500 V Accuracy (± reading)Unspecified 5% 20% Unspecified
5000 V Range1 TΩ
5000 V Accuracy (± reading)Unspecified 5% 20% Unspecified
Bar graph range0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555)
Insulation test voltage accuracy-0%, +10% at 1 mA load current
Induced AC mains current rejection2 mA maximum
Charging rate for capacitive load5 seconds per μF
Discharge rate for capacitive load1.5 s/μF
Leakage current measurement Range1 nA to 2 mA
Leakage current measurement Accuracy± (20% + 2 nA)
Capacitance measurement Range0.01 μF to 15.00 μF
Capacitance measurement Accuracy± (15% rdg + 0.03 μF)
Timer Range0 to 99 minutes
Timer Resolution setting1 minute
Timer Resolution indication1 second
Live circuit warning Warning range30 V to 660 V AC/DC, 50/60 Hz
Live circuit warning Voltage accuracy± (15% + 2 V)
Software specificationsFlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.
Display75 x 105 mm
Power12 V lead-acid rechargeable battery, Yuasa NP2.8-12
Charger Input (AC)85 V to 250 V AC 50/60 Hz 20 VA
Dimensions269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in)
Weight3.7 kg (8.2 lb)
Temperature (operating)-20°C to 50°C (-4°F to 122°F)
Temperature (storage)-20°C to 65°C (-4°F to 149°F)
Humidity80% to 31°C decreasing linearly to 50% at 50°C
Altitude2000 m
Enclosure sealingIP40
Input overload protection1000 V AC
Electromagnetic compatibilityEN 61326
Safety complianceIEC 61010-1: Overvoltage category II
Pollution Degree 2
IEC 61010-2-030Measurement 600V CAT IV / 1000V CAT III IEC 61557-1, IEC 61557-2

Properties

MOQ1

Cross-References