cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-08
sales@cballast.com
cballast.com

Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
4296029  ·  HS 9030.33
Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter

Combine the power of Fluke's 116 HVAC Multimeter with a Fluke 323 clamp meter for productive and effective troubleshooting.

Technical Specifications

Manufacturer part number (MPN)4296029
BrandFluke
CategoryTools
Maximum voltage between any terminal and earth ground600 V
Surge protection6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Battery type9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life400 hours typical, without backlight
DC millivolts Range/Resolution600.0 mV / 0.1 mV
DC millivolts Accuracy±([% of reading] + [counts]): 0.5% + 2
DC volts Range/Resolution6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V
DC volts Accuracy±([% of reading] + [counts]): 0.5% + 2
Auto volts Range/Resolution600.0 V / 0.1 V
Auto volts Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMS Range/Resolution600.0 mV / 0.1 mV
AC millivolts¹ True RMS Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMS Range/Resolution6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V
AC volts¹ True RMS Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/Resolution600 Ω / 1 Ω
Continuity AccuracyBeeper on 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms Range/Resolution600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ
Ohms Accuracy0.9% + 1
Diode test Range/Resolution2.000 V / 0.001 V
Diode test Accuracy0.9% + 2
Capacitance Range/Resolution1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF
Capacitance Accuracy1.9% + 2
LoZ capacitance Range1 nF to 500 μF
LoZ capacitance Accuracy10% + 2 typical
Temperature² (Type-K thermocouple) Range/Resolution-40°C to 400°C / 0.1°C
Temperature² (Type-K thermocouple) Accuracy1% + 10²
AC μamps True RMS (45 Hz to 500 Hz) Range/Resolution600.0 μA / 0.1 μA
AC μamps True RMS (45 Hz to 500 Hz) Accuracy1.0% + 2
DC μamps Range/Resolution600.0 μA / 0.1 μA
DC μamps Accuracy1.0% + 2
Hz (V or A input)² Range/Resolution99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz
Hz (V or A input)² Accuracy0.1% + 2
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years
AC current Range400.0 A
AC current Accuracy2% ±5 digits (45 Hz to 65 Hz) 2.5% ±5 digits (65 Hz to 400 Hz)
AC voltage Range600.0 V
AC voltage Accuracy1.5% ±5 digits
DC voltage Range600.0 V
DC voltage Accuracy1.0% ±5 digits
Resistance Range/Resolution400.0 Ω/ 4000 Ω
Resistance Accuracy1.0% ±5 digits
Continuity≤ 70 Ω
AC responseTrue-rms
Data holdYes
Size H x W x D (mm)207 x 75 x 34
Size Max wire diameter30 mm (600 MCM)
Size Weight265 g
Category ratingCAT III 600 V CAT IV 300 V

Properties

MOQ1

Cross-References

Attached Documents