cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Fluke 115 Field Technicians Digital Multimeter

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
2538790  ·  HS 9030.33
Fluke 115 Field Technicians Digital Multimeter

Get the Fluke 115 True-RMS digital multimeter for all electrical and electronic test requirements. Simple operation, compact design, & easy to use. Buy Now!

Technical Specifications

Manufacturer part number (MPN)2538790
BrandFluke
CategoryTools
Fluke 115 Field Technicians Digital MultimeterFluke 117 Electrician's Multimeter
DC millivolts Range/resolution600.0 mV / 0.1 mV
DC millivolts Accuracy± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V
DC volts Accuracy± ([% of reading] + [counts]): 0.5% + 2
AC millivolts1 True RMS Range/resolution600.0 mV / 0.1 mV
AC millivolts1 True RMS Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS Range/resolution6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V
AC volts1 True RMS Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution600 Ω / 1 Ω
Continuity AccuracyBeeper on 250 Ω detects opens or shorts of 500 μs or longer.
Ohms Range/resolution600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ
Ohms Accuracy0.9% + 1
Diode test Range/resolution2.00 V / 0.001 V
Diode test Accuracy0.9% + 2
Capacitance Range/resolution1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF
Capacitance Accuracy1.9% + 2
Lo-Z capacitance Range1 nF to 500 μF
Lo-Z capacitance Accuracy10% + 2 typical
AC amps True RMS (45 Hz to 500Hz) Range/resolution6.000 A / 0.001 A 10.00 A / 0.01 A
AC amps True RMS (45 Hz to 500Hz) Accuracy1.5% + 3 20 A overload for 30-seconds max
DC amps Range/resolution6.000 A / 0.001 A 10.00 A / 0.01 A
DC amps Accuracy1.0% + 3 20 A overload for 30-seconds max
Hz (V or A input)2 Range/resolution99.99 Hz / 0.01 Hz 999.9 Hz / 0.01 Hz 9.999 kHz / 0.001 kHz 50.00 kHz / 0.01 kHz
Hz (V or A input)2 Accuracy0.1% + 2
Maximum voltage between any terminal and earth ground600 V
SafetyIEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10℃ to + 50℃
Storage temperature-40℃ to + 60℃
Battery type9 volt Alkaline, IEC 6LR61
Battery life400 hours typical, without backlight
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years

Properties

MOQ1

Cross-References

Attached Documents