cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

eMobility Tools Kit with FEV100 Test Adapter, 87V Multimeter and Test Leads

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
5348150  ·  HS 9030.33
eMobility Tools Kit with FEV100 Test Adapter, 87V Multimeter and Test Leads

Ideal for EVSE installation technicians, the Fluke eMobility Tools Kit includes the FEV100 test adapter, multimeter and test leads.

Technical Specifications

Manufacturer part number (MPN)5348150
BrandFluke
CategoryTools
Input voltageUL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 208 V, 60 Hz (three-phase system) or UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 240 V, 60 Hz (single-phase system), ±10% voltage fluctuations from nominal
EV connector (EVC-13)SAE J1772 socket, 16 A (type 1, 5P single-phase)
Internal power consumption2 W max.
Operating temperature-4 °F to 104 °F (-20 °C to 40 °C)
Storage temperature-4 °F to 122 °F (-20 °C to 50 °C)
Operating humidity range10 % to 85 % relative humidity non-condensing
Storage relative humidity0 % to 85 % non-condensing
Operating altitude6561 ft (2000 m) max.
Dimensions (H × W × D)Approx. 8.66 x 4.33 x 1.77 in (220 x 110 × 45 mm) without cable assembly
WeightApprox. 4.4 lb (2 kg)
Safety standardsIEC 61010-1, Pollution Degree 2 IEC 61010-2-030
Measurement categoryCAT II 250 V
IP protection classIP54
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
CP StatesA, B, C, D
CP Error “E”On/off
PE ErrorOn/off
GFCI TestYes, test resistor of 2 kΩ connected between L1 and PE, time limitation 40 ms
PE Pre-Test (typical)Visible indication >30 V on PE conductor
Measuring terminals L1, L2/N
PEMax. 250 V 50/60 Hz, CAT II 250 V
CP signal output terminalsApprox. ±12 V (under normal conditions), in case of wrong wiring or error of the charging station these terminals can be hazardous ≥ max. 250 V against PE
Voltage DC Maximum voltage1000 V
Voltage DC Accuracy±(0.05% + 1)
Voltage DC Maximum resolution10 µV
Voltage AC Maximum voltage1000 V
Voltage AC Accuracy±(0.7% + 2) True RMS
Voltage AC AC bandwidth20 kHz with low pass filter; 3 dB @ 1 kHz
Voltage AC Maximum resolution0.1 mV
Current DC Maximum amps10 A (20 A for 30 seconds maximum)
Current DC Amps accuracy±(0.2% + 2)
Current DC Maximum resolution0.01 µA
Current AC Maximum amps10 A (20 A for 30 seconds maximum)
Current AC Amps accuracy±(1.0% + 2) True RMS
Current AC Maximum resolution0.1 µA
Resistance Maximum resistance50 MΩ
Resistance Accuracy±(0.2% + 1)
Resistance Maximum resolution0.1 Ω
Capacitance Maximum capacitance9,999 µF
Capacitance accuracy±(1% + 2)
Capacitance Maximum resolution0.01 nF
Frequency Maximum frequency200 kHz
Frequency Accuracy±(0.005% + 1)
Frequency Maximum resolution0.01 Hz
Duty cycle Maximum duty cycle99.9%
Duty cycle Accuracy±(0.2% per kHz + 0.1%)
Duty cycle Maximum resolution0.1%
Temperature measurement–200.0 °C – 1090 °C –328.0 °F – 1994.0 °F excluding probe
80 BK temperature probe–40.0 °C – 260 °C –40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater
Conductance Maximum conductance60.00 nS
Conductance Accuracy±(1.0% + 10)
Conductance Maximum resolution0.01 nS
Diode Range3 V
Diode Resolution1 mV
Diode Accuracy±(2% + 1)
Duty cycle range AccuracyWithin ±(0.2% per kHz + 0.1%)
Humidity (without condensation)0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C)
Overvoltage categoryEN 61010–1 to 1000 V CAT III, 600V CAT IV
Agency approvalsCE, CSA, RCM
Size201 x 98 x 52 mm (with holster)
Display Digital6000 counts updates 4/sec. 19,999 counts in high–resolution mode
Display Analog32 segments, updates 40/sec
Display Frequency19,999 counts, updates 3/sec at > 10 Hz
WarrantyLifetime
Battery Life Alkaline~400 hours typical, without backlight
Shock1 Meter drop per IEC 61010–1:2001
VibrationPer MIL–PRF–28800 for a Class 2 instrument

Properties

MOQ1

Cross-References

Attached Documents