| Manufacturer part number (MPN) | 5348150 |
| Brand | Fluke |
| Category | Tools |
| Input voltage | UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 208 V, 60 Hz (three-phase system) or UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 240 V, 60 Hz (single-phase system), ±10% voltage fluctuations from nominal |
| EV connector (EVC-13) | SAE J1772 socket, 16 A (type 1, 5P single-phase) |
| Internal power consumption | 2 W max. |
| Operating temperature | -4 °F to 104 °F (-20 °C to 40 °C) |
| Storage temperature | -4 °F to 122 °F (-20 °C to 50 °C) |
| Operating humidity range | 10 % to 85 % relative humidity non-condensing |
| Storage relative humidity | 0 % to 85 % non-condensing |
| Operating altitude | 6561 ft (2000 m) max. |
| Dimensions (H × W × D) | Approx. 8.66 x 4.33 x 1.77 in (220 x 110 × 45 mm) without cable assembly |
| Weight | Approx. 4.4 lb (2 kg) |
| Safety standards | IEC 61010-1, Pollution Degree 2 IEC 61010-2-030 |
| Measurement category | CAT II 250 V |
| IP protection class | IP54 |
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
| CP States | A, B, C, D |
| CP Error “E” | On/off |
| PE Error | On/off |
| GFCI Test | Yes, test resistor of 2 kΩ connected between L1 and PE, time limitation 40 ms |
| PE Pre-Test (typical) | Visible indication >30 V on PE conductor |
| Measuring terminals L1, L2/N |
| PE | Max. 250 V 50/60 Hz, CAT II 250 V |
| CP signal output terminals | Approx. ±12 V (under normal conditions), in case of wrong wiring or error of the charging station these terminals can be hazardous ≥ max. 250 V against PE |
| Voltage DC Maximum voltage | 1000 V |
| Voltage DC Accuracy | ±(0.05% + 1) |
| Voltage DC Maximum resolution | 10 µV |
| Voltage AC Maximum voltage | 1000 V |
| Voltage AC Accuracy | ±(0.7% + 2) True RMS |
| Voltage AC AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz |
| Voltage AC Maximum resolution | 0.1 mV |
| Current DC Maximum amps | 10 A (20 A for 30 seconds maximum) |
| Current DC Amps accuracy | ±(0.2% + 2) |
| Current DC Maximum resolution | 0.01 µA |
| Current AC Maximum amps | 10 A (20 A for 30 seconds maximum) |
| Current AC Amps accuracy | ±(1.0% + 2) True RMS |
| Current AC Maximum resolution | 0.1 µA |
| Resistance Maximum resistance | 50 MΩ |
| Resistance Accuracy | ±(0.2% + 1) |
| Resistance Maximum resolution | 0.1 Ω |
| Capacitance Maximum capacitance | 9,999 µF |
| Capacitance accuracy | ±(1% + 2) |
| Capacitance Maximum resolution | 0.01 nF |
| Frequency Maximum frequency | 200 kHz |
| Frequency Accuracy | ±(0.005% + 1) |
| Frequency Maximum resolution | 0.01 Hz |
| Duty cycle Maximum duty cycle | 99.9% |
| Duty cycle Accuracy | ±(0.2% per kHz + 0.1%) |
| Duty cycle Maximum resolution | 0.1% |
| Temperature measurement | –200.0 °C – 1090 °C –328.0 °F – 1994.0 °F excluding probe |
| 80 BK temperature probe | –40.0 °C – 260 °C –40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater |
| Conductance Maximum conductance | 60.00 nS |
| Conductance Accuracy | ±(1.0% + 10) |
| Conductance Maximum resolution | 0.01 nS |
| Diode Range | 3 V |
| Diode Resolution | 1 mV |
| Diode Accuracy | ±(2% + 1) |
| Duty cycle range Accuracy | Within ±(0.2% per kHz + 0.1%) |
| Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) |
| Overvoltage category | EN 61010–1 to 1000 V CAT III, 600V CAT IV |
| Agency approvals | CE, CSA, RCM |
| Size | 201 x 98 x 52 mm (with holster) |
| Display Digital | 6000 counts updates 4/sec. 19,999 counts in high–resolution mode |
| Display Analog | 32 segments, updates 40/sec |
| Display Frequency | 19,999 counts, updates 3/sec at > 10 Hz |
| Warranty | Lifetime |
| Battery Life Alkaline | ~400 hours typical, without backlight |
| Shock | 1 Meter drop per IEC 61010–1:2001 |
| Vibration | Per MIL–PRF–28800 for a Class 2 instrument |