cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Best HVAC Multimeter - Fluke 116 Digital HVAC Multimeter

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
2538803  ·  HS 9030.33
Best HVAC Multimeter - Fluke 116 Digital HVAC Multimeter

Get the right HVAC multimeter for accurate temperature & microamp measurements. The Fluke 116 digital multimeter has everything you need in an HVAC meter.

Technical Specifications

Manufacturer part number (MPN)2538803
BrandFluke
CategoryTools
Maximum voltage between any terminal and earth ground600 V
SafetyIEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10°C to + 50°C
Storage temperature-40°C to + 60°C
Battery type9 volt Alkaline, IEC 6LR61
Battery life400 hours typical, without backlight
DC millivolts Range/resolution600.0 mV / 0.1 mV
DC millivolts Accuracy±([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V
DC volts Accuracy±([% of reading] + [counts]): 0.5% + 2
Auto volts Range/resolution600.0 V / 0.1 V
Auto volts Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS Range/resolution600.0 mV / 0.1 mV
AC millivolts1 True RMS Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS Range/resolution6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V
AC volts1 True RMS Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution600 Ω / 1 Ω
Continuity AccuracyBeeper on 250 Ω detects opens or shorts of 500 μs or longer.
Ohms Range/resolution600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ
Ohms Accuracy0.9% + 1
Diode Test Range/resolution2.00 V / 0.001 V
Diode Test Accuracy0.9% + 2
Capacitance Range/resolution1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF
Capacitance Accuracy1.9% + 2
Lo-Z Capacitance Range1 nF to 500 μF
Lo-Z Capacitance Accuracy10% + 2 typical
Temperature² (Type-K thermocouple) Range/resolution-40°C to 400°C / 0.1°C
Temperature² (Type-K thermocouple) Accuracy1% + 10²
AC μA true-rms (45 Hz to 500 Hz) Range/resolution600.0 μA / 0.1 μA
AC μA true-rms (45 Hz to 500 Hz) Accuracy1.5% + 3
DC μamps Range/resolution600.0 μA / 0.1 μA
DC μamps Accuracy1.0% + 2
Hz (V or A input)² Range/resolution99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz
Hz (V or A input)² Accuracy0.1% + 2
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years

Properties

MOQ1

Cross-References