| Manufacturer part number (MPN) | 787B |
| EAN / GTIN | 0095969819930 |
| Sales unit | pcs |
| Manufacturer model | Fluke 787B |
| V dc | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 0.1% + 1 |
| V ac (true-rms) | 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 0.7% + 2 |
| mA dc | 30.000 mA .05% + 2 |
| A dc | 1.000 A (0.440 A continuous) 0.2% + 2 |
| A ac | 1.000 A (0.440 A continuous) 1% + 2 |
| Resistance | 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M 0.2% + 1 |
| Frequency (0.5 Hz to 20 kHz) | 199.99 Hz, 1999.9 Hz, 19.999 kHz .005% + 1 |
| Diode test | 2.000 V (shows diode voltage drop) 2% + 1 |
| Continuity | Beeps for resistance |
| DC current output (Internal battery operation) | 0.000 to 20.000 mA or 4.000 to 20.000 mA, (selectable at power-up) Over-range to 24.000 mA 24 V compliance or, 1,200 ohms, @ 20 mA 0.05% |
| Current adjustment modes | Manual: Coarse, Fine, 25% and 100% step |
| Storage temperature | -40 °C to 60 °C |
| Operating temperature | -20 °C to 55 °C |
| Temperature coefficient | 0.05 x (specified accuracy) per °C (for temperatures 28 °C) |
| Relative humidity | 95% up to 30 °C; 75% up to 40 °C; 45% up to 50 °C; 35% up to 55 °C |