cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Input module temperature (172560)

Eaton · Control & Automation · PLCs & Industrial Networking · Ireland · eaton.com
Part Number
172560  ·  HS 8538.90
Input module temperature (172560)

Eaton 172560 EU5E-SWD-4PT-2.

Technical Specifications

Manufacturer part number (MPN)172560
EAN / GTIN4015081691050
Sales unitpcs
Eaton catalogue number172560
Depth102 mm
Height90 mm
Width35 mm
Weight0.16 kg
CertificationsCSA File No.: 2324643; CSA Class No.: 3211-07; UL File No.: E29184; IEC/EN 61131-2; UL; UL Category Control No.: NKCR; CSA
Constant acceleration1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
Constant amplitude3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
Drop and topple50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max0.3 m
Mounting positionAs required
Shock resistance15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
Air pressure795 - 1080 hPa (operation)
Ambient operating temperature - max55 °C
Ambient storage temperature - max70 °C
Ambient operating temperature - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-3; Dry heat to IEC 60068-2-2
Environmental conditionsCondensation: prevent with appropriate measures
Operating temperature - max55 °C
Operating temperature - min-100 °C
Relative humidity5 - 95 % (non-condensing, IEC/EN 60068-2-30)
Connection to SmartWire-DTYes
Connection typePin contact, 8 pole; Push in terminals
Supply and I/O sensor; Connectorexternal device plug SWD4-8SF2-5, SmartWire-DT
Data transfer rateSetting automatically; 250 kBit/s, SmartWire-DT
LED indicatorStatus indication of SmartWire-DT network: Green LED
ProtocolOther bus systems
StationSmartWire-DT slave, SmartWire-DT network
Static heat dissipation, non-current-dependent Pvs0.6 W
Power loss0.6 W
Rated operational voltage24 V DC (-15 %/+ 20 % - power supply)
Air discharge8 kV, according to IEC 61131-2, level 3, ESD
Burst impulse2 kV, Signal cable, according to IEC/EN 61131-2, Level 3; 2 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3; 2 kV, Supply cable, according to IEC/EN 61131-2, Level 3
Contact discharge4 kV, according to IEC/EN 61131-2, Level 2, ESD
Electromagnetic fields10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008); 1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008); 3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008)
Radiated RFI10 V (IEC/EN 61131-2:2008, Level 3)
Radio interference classClass B (EN 55011)
Surge rating1 kV, Surge I/O cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC; 1 kV, Surge power cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC
Electric connection typeFlat plug-in connection
FeaturesFieldbus connection over separate bus coupler possible; Analog outputs configurable; Input, resistance thermometer; Analog inputs configurable; Fieldbus connection over separate bus coupler possible
Fitted withTemperature sensors PT100, PT1000 and Ni1000; Display mode for temperatures (°C, °F, raw value)
FunctionsAdjustable parameter settings; For connection of analog I/O signals
Current consumption22 mA, SmartWire-DT network
Degree of protectionIP20; NEMA 1
Mounting methodRail mounting possible; Wall mounting/direct mounting; Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Overvoltage categoryII
Pollution degree2
Product categorySmartWire-DT slave
Repetition accuracy0.5 % (Temperature inputs)
Residual ripple≤ 5 % (input voltage)
Terminal capacity0.25 - 1.5 mm² (24 - 16 AWG), flexible with ferrule, Terminal for I/O sensor; 0.2 - 1.5 mm² (AWG 24 - 16), solid, Terminal for I/O sensor
TypeAnalog modules
Voltage typeDC
Conversions250 ms, Temperature inputs
InputInputs, configurable (PT100, PT1000, Ni1000)
Number of inputs (analog)4
Number of outputs (analog)0
Resolution0.1 °C, Temperature inputs
Total error± 1 %, Temperature Inputs
Explosion safety category for dustNone
Explosion safety category for gasNone
Potential isolationInputs for SmartWire-DT: yes
Protection against polarity reversalYes
Power consumption0.6 W
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Input, currentNo
Input, voltageNo
Input, resistorNo
Input, resistance thermometerYes
Input, thermocoupleNo
Input signal, configurableNo
Resolution of the analogue inputs12 Bit
Output, currentNo
Output, voltageNo
Output signal configurableNo
Number of analogue inputs4
Analogue inputs configurableYes
Analogue outputs configurableYes
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsYes
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
IO link masterNo
System accessoryYes
Type of electric connectionFlat plug-in connection
Fieldbus connection over separate bus coupler possibleYes
Suitable for rail mountingYes
Wall mounting/direct mountingYes
Front built-in possibleNo
Rack-assembly possibleNo
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Country of originGermany

Properties

MOQ1

Cross-References

Attached Documents