| Manufacturer part number (MPN) | XN-2DO-120/230VAC-0.5A |
| EAN / GTIN | 7640130120198 |
| Sales unit | pcs |
| Eaton catalogue number | 140150 |
| Depth | 55.4 mm |
| Height | 74.1 mm |
| Width | 12.6 mm |
| Weight | 0.035 kg |
| Certifications | UL 508; IEC/EN 61000-6-4; Certified by UL for use in Canada; cULus; UL Recognized; CE; IEC/EN 61131-2; IEC/EN 61000-6-2; UL File No.: E205091; UL report applies to both US and Canada; CSA Class No.: 2252-01 |
| 2252-81; CSA-C22.2 No. 142; UL Category Control No. | NRAQ, NRAQ7; IEC/EN 6113-2 |
| Catalog Notes | 8 (1 period at 60 Hz) |
| Drop and topple | According to IEC 60068-2-31, free fall according to IEC 60068-2-32 |
| Shock resistance | Mechanical, According to IEC/EN 60068-2-27; Continuous according to IEC/EN 60068-2-29 |
| Vibration resistance | According to IEC/EN 60068-2-6 |
| Ambient operating temperature - max | 55 °C |
| Ambient storage temperature - max | 85 °C |
| Ambient operating temperature - min | 0 °C |
| Ambient storage temperature - min | -25 °C |
| Environmental conditions | Harmful gasses - H2S: 1 ppm (relative humidity < 75%, no condensation); Harmful gasses - SO2: 10 ppm (relative humidity < 75%, no condensation) |
| Relative humidity | 5 - 95 % (indoor, Level RH-2, non-condensing for storage at 45°C) |
| Interfaces | Terminating resistor: 240 - 6,000 Ω (at 120 V AC); Terminating resistor: 460 - 11,500 Ω (at 230 V AC) |
| Protocol | Other bus systems |
| Static heat dissipation, non-current-dependent Pvs | 1 W |
| Power loss | 1 W |
| Rated operational voltage | 120/230 V AC at 45-64 Hz (supply terminal) |
| Supply voltage at AC |
| 50 Hz - max | 253 VAC |
| Supply voltage at AC |
| 50 Hz - min | 102 VAC |
| Air discharge | According to EN 61100-4-2 |
| Burst impulse | According to IEC/EN 61000-4-4 |
| Contact discharge | According to EN 61100-4-2 |
| Electromagnetic fields | According to IEC EN 61100-4-2 |
| Emitted interference | 30 - 230 MHz (radiated, high frequency, according to EN 55016-2-3); 230 - 1000 MHz (radiated, high frequency, according to EN 55016-2-3) |
| Radiated RFI | IEC/EN 61100-4-6 |
| Surge rating | According to IEC/EN 61000-4-5 Level 4 |
| Voltage dips | According to EN 61131-2 (Voltage fluctuations/voltage dips) |
| Electric connection type | Screw-/spring clamp connection |
| Features | Fieldbus connection over separate bus coupler possible |
| Fitted with | Connectable sensors for inductive loads; Connectable sensors for lamp loads; Connectable sensors for resistive loads |
| Current consumption | 35 mA, from module bus, Analog input modules |
| Degree of protection | IP20 |
| Mounting method | Rail mounting possible |
| Product category | XN Slice module |
| Suitable for | Base modules with C-connection: 2-wire/3-wire; Base modules with C-connection: 4-wire |
| Type | XI/ON I/O module |
| Used with | XN-S3T-SBC; XN-S3S-SBC; XN-S4S-SBCS; XN-S4T-SBCS |
| Voltage type | AC |
| Number of channels | 2 |
| Delay time | T/2 +1 ms, Digital outputs, Delay on signal change and resistive load, from Low to High signal; 300, Digital outputs, Delay on signal change and resistive load, from High to Low signal |
| Input voltage | > U low level - 2 V (Digital inputs, high level) |
| Number of inputs (digital) | 0 |
| Number of outputs (digital) | 2 |
| Output | 2 Digital Outputs (120/230 V AC, 0.5 A) |
| Output current | 1 A, Module total current, Digital outputs; 0.5 A; 0.02 - 0.5 A (high level, permissible range); < 1.5 mA (low level) |
| Output voltage | > U low level - 2 V (zero-point switching triac) |
| Utilization factor | 100 %; 100 % (observe derating) |
| Explosion safety category for dust | None |
| Explosion safety category for gas | None |
| Potential isolation | Through optocoupler: yes |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | No |
| Certified for UL hazardous location group A (acetylene) | No |
| Certified for UL hazardous location group B (hydrogen) | No |
| Certified for UL hazardous location group C (ethylene) | No |
| Certified for UL hazardous location group D (propane) | No |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location class I | No |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Supporting protocol for EtherCAT | No |
| Supply voltage AC 50 Hz | 102–253 V |
| Supply voltage AC 60 Hz | 102–253 V |
| Number of digital outputs | 2 |
| Digital inputs configurable | No |
| Digital outputs configurable | No |
| Type of voltage (input voltage) | AC |
| Type of digital output | Triac |
| Permitted voltage at output | 0–251 V |
| Type of output voltage | AC |
| Short-circuit protection, outputs available | No |
| Number of HW-interfaces other | 1 |
| With optical interface | No |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | Yes |
| Supporting protocol for CAN | Yes |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | Yes |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | Yes |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| IO link master | No |
| System accessory | Yes |
| Type of electric connection | Plug-in connection |
| Time delay at signal change | 0–11 ms |
| Fieldbus connection over separate bus coupler possible | Yes |
| Suitable for rail mounting | Yes |
| Wall mounting/direct mounting | No |
| Front built-in possible | No |
| Rack-assembly possible | No |
| Suitable for safety functions | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Country of origin | Germany |