Gateway to bus system CANopen (178782)

Eaton · Control & Automation · Fieldbus I/O · Ireland · eaton.com
Part Number
178782  ·  HS 8537.10
Gateway to bus system CANopen (178782)

Eaton 178782 Gateway for bus system CANopen.

Technical Specifications

Manufacturer part number (MPN)178782
EAN / GTIN7640130098442
Sales unitpcs
Eaton catalogue number178782
Depth104.2 mm
Height16.8 mm
Width80.3 mm
Weight0.061 kg
CertificationsCE; DNV GL; IEC/EN 61000-6-2; cULus; IEC/EN 61131-2; UL File No.: E135462; IEC/EN 61000-6-4; UL508; Rated data for terminations according to IEC/EN 60947-7-1
Drop and toppleAccording to IEC 60068-2-31, free fall according to IEC 60068-2-32
Shock resistanceMechanical, According to IEC/EN 60068-2-27
Vibration resistanceAccording to IEC/EN 60068-2-6
Ambient operating temperature - max85 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient storage temperature - min-40 °C
Relative humidity5 - 95 % (non-condensing)
AddressingAddress set via DIP switch
Bus terminationVia DIP switch, Networking
Connection typePush-In spring-cage terminals, Field bus; Push-In spring-cage terminals, Connection design in TOP direction
Data transfer rateSetting through DIP switch or automatically; 1000 kBit/s, Networking; 10 kBit/s, Networking; 125 kBit/s, Networking; 20 kBit/s, Networking; 500 kBit/s, Networking; 50 kBit/s, Networking; 250 kBit/s, Networking; 800 kBit/s, Networking
Field voltage24 V DC (UL)
InterfacesCANopen®, Field bus connection; Mini-USB Type B (Service interface)
ProtocolCAN; CANopen®; Other bus systems
Static heat dissipation, non-current-dependent Pvs2.4 W
Supply voltage4.7 - 5.3 V DC
Supply voltage at DC - max30 V
Supply voltage at DC - min18 V
Air dischargeAccording to EN 61131-2
Burst impulseAccording to IEC/EN 61131-2
Contact dischargeAccording to EN 61131-2
Electromagnetic fieldsAccording to EN 61131-2
Emitted interference30 - 230 MHz (radiated, high frequency, according to EN 61131-2); 230 - 1000 MHz (radiated, high frequency, according to EN 61131-2)
Radiated RFIIEC/EN 61131-2
Surge ratingAccording to IEC/EN 61131-2
Voltage dipsAccording to EN 61131-2 (Voltage fluctuations/voltage dips)
FeaturesFieldbus connection over separate bus coupler possible; Fieldbus connection over separate bus coupler possible
Fitted withPotential separation
Admissible range18 - 30 V DC, Networking; 19.2 - 30 V DC, Networking
ConfigurationMaximum station configuration: 32 modules (XN-322) in slice design
Degree of protectionIP20
Mounting methodRail mounting possible
Residual rippleAccording to EN 61131-2
TypeCANopen XN-312 gateway for XN300 Digital gateway for CANopen field bus in the form of an XN300 I/O system slice module XN300 CANopen gateway for running XN300 slice modules on a CANopen field bus XN300 gateway
Used withXN-322-…; XN300
Voltage typeDC
Explosion safety category for dustNone
Explosion safety category for gasNone
Potential isolationYes
Gauge pinA1 (according to IEC/EN 60947-1)
Stripping length (main cable)10 mm
Terminal capacity0.2 - 1.5 mm², flexible without ferrule, H07V-K; 0.25 - 1.5 mm², with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight); 0.2 - 1.5 mm², solid, H07V-U; 0.25 - 1.5 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
Number of HW-interfaces other1
Number of HW-interfaces USB1
Number of HW-interfaces CAN1
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Supply voltage DC18–30 V
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANYes
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsYes
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard eGPRSNo
Radio standard GSMNo
Radio standard LTENo
Mobile communications standard 3G (UMTS)No
IO link masterNo
System accessoryYes
With potential separationYes
Fieldbus connection over separate bus coupler possibleYes
Suitable for rail mountingYes
Wall mounting/direct mountingNo
Front built-in possibleNo
Rack-assembly possibleNo
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Country of originAustria