cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

BUS Refereshing MOD.24VDC (XN-BR-24VDC-D)

Eaton · Control & Automation · PLCs & Logic Relays · Ireland · eaton.com
Part Number
XN-BR-24VDC-D  ·  HS 8536.90
BUS Refereshing MOD.24VDC (XN-BR-24VDC-D)

Technical Specifications

Manufacturer part number (MPN)XN-BR-24VDC-D
EAN / GTIN7640130120518
Sales unitpcs
Eaton catalogue number140071
Depth55.4 mm
Height74.1 mm
Width12.6 mm
Weight0.037 kg
CompliancesRoHS Compliant; CE Marked
CertificationsUL Listed; IEC/EN 61000-6-4; UL report applies to both US and Canada; UL 508; CE; Certified by UL for use in Canada; CSA Class No.: 2252-01
2252-81; IEC/EN 61131-2; UL Category Control No.NRAQ
NRAQ7; cULus; UL File No.E205091; UL Recognized; CSA-C22.2 No. 142; IEC/EN 61000-6-2; IEC/EN 6113-2
Catalog NotesSystem power supply 24 V DC for generation of power for module bus and gateway (XN-GW-... )
Drop and toppleAccording to IEC 60068-2-31, free fall according to IEC 60068-2-32
Shock resistanceContinuous according to IEC/EN 60068-2-29; Mechanical, According to IEC/EN 60068-2-27
Vibration resistanceAccording to IEC/EN 60068-2-6
Ambient operating temperature - max55 °C
Ambient storage temperature - max85 °C
Ambient operating temperature - min0 °C
Ambient storage temperature - min-25 °C
Environmental conditionsHarmful gasses - SO2: 10 ppm (relative humidity < 75%, no condensation); Harmful gasses - H2S: 1 ppm (relative humidity < 75%, no condensation)
Relative humidity5 - 95 % (indoor, Level RH-2, non-condensing for storage at 45°C)
Field voltage24 V DC (UL)
Number of bytes4 diagnostic bytes
ProtocolOther bus systems
Static heat dissipation, non-current-dependent Pvs1.3 W
Power lossNormally 1.3 W
Rated insulation voltage (Ui)500 V
Supply current1.5 A, IMB, Maximum system supply current, Supply modules; 10 A, IEI, Maximum operating current, Supply modules
Supply voltage at AC
Supply voltage at AC
Supply voltage at DC - max30 VDC
Supply voltage at DC - min18 VDC
Air dischargeAccording to EN 61000-4-2
Burst impulseAccording to IEC/EN 61000-4-4
Electromagnetic fieldsAccording to IEC EN 61100-4-2
Emitted interference30 - 230 MHz (radiated, high frequency, according to EN 55016-2-3); 230 - 1000 MHz (radiated, high frequency, according to EN 55016-2-3)
Radiated RFIIEC/EN 61100-4-6
Surge ratingAccording to IEC/EN 61000-4-5 Level 4
Voltage dipsAccording to EN 61131-2 (Voltage fluctuations/voltage dips)
Electric connection typeScrew-/spring clamp connection
FeaturesFieldbus connection over separate bus coupler possible
Fitted withPotential separation
FunctionsBus diagnosis possible
Admissible range18 - 30 V DC, Supply module
Degree of protectionIP20
Mounting methodRail mounting possible
Product categoryXN Slice module
Residual ripple< 5 % (according to EN 61131-2)
Suitable asSegment module
Suitable forBase modules without C-Connection: 2-/3-wire; Base modules with C-connection: 4-wire
TypeXI/ON power supply module
Used withXN-P3T-SBB; XN-P3S-SBB; XN-P4S-SBBC-B; XN-P4S-SBBC, XN-P3T-SBB-B; XN-P4T-SBBC; XN-P4T-SBBC-B; XN-P3S-SBB-B; XN-P4S-SBBC; XN-P3T-SBB-B
Voltage typeDC
Explosion safety category for dustNone
Explosion safety category for gasNone
Potential isolationThrough optocoupler: yes
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Supply voltage DC18–30 V
Number of HW-interfaces other1
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsYes
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
System accessoryYes
Type of electric connectionScrew-/spring clamp connection
With potential separationYes
With power supply moduleNo
Suitable as segment moduleYes
Remote moduleNo
Fieldbus connection over separate bus coupler possibleYes
Bus diagnosis possibleYes
Suitable for rail mountingYes
Wall mounting/direct mountingNo
Front built-in possibleNo
Rack-assembly possibleNo
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Country of originGermany

Properties

MOQ1

Cross-References

Attached Documents