| Manufacturer part number (MPN) | XNE-GWBR-2ETH-MB |
| EAN / GTIN | 7640130095298 |
| Sales unit | pcs |
| Eaton catalogue number | 152279 |
| Depth | 129 mm |
| Height | 75 mm |
| Width | 33.5 mm |
| Weight | 0.136 kg |
| Certifications | cULus; CE |
| Ambient operating temperature - max | 55 °C |
| Ambient operating temperature - min | 0 °C |
| Addressing | Address set via DIP switch, BootP, DHCP or PGM |
| Connection type | 2 x RJ45 (Ethernet Switch), Field bus; Push-In spring-cage terminals, Connection design in TOP direction |
| Data transfer rate | 10/100 MBit/s |
| Interfaces | Ethernet (Modbus-TCP protocol), Field bus connection |
| Protocol | MODBUS; Other bus systems |
| Static heat dissipation, non-current-dependent Pvs | 8 W |
| Supply voltage at DC - max | 30 V |
| Supply voltage at DC - min | 18 V |
| Features | Fieldbus connection over separate bus coupler possible; Fieldbus connection over separate bus coupler possible |
| Fitted with | Potential separation |
| Accessories | 1 x end plate XN-ABPL and 2 x end bracket XN-WEW-32/2-SW included with supplied equipment. |
| Degree of protection | IP20 |
| Mounting method | Rail mounting possible |
| Type | XI/ON ECO gateways |
| Voltage type | DC |
| Explosion safety category for dust | None |
| Explosion safety category for gas | None |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | No |
| Certified for UL hazardous location group A (acetylene) | No |
| Certified for UL hazardous location group B (hydrogen) | No |
| Certified for UL hazardous location group C (ethylene) | No |
| Certified for UL hazardous location group D (propane) | No |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location class I | No |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Supporting protocol for EtherCAT | No |
| Supply voltage DC | 18–30 V |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | Yes |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | No |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard eGPRS | No |
| Radio standard GSM | No |
| Radio standard LTE | No |
| Mobile communications standard 3G (UMTS) | No |
| IO link master | No |
| System accessory | Yes |
| With potential separation | Yes |
| Fieldbus connection over separate bus coupler possible | Yes |
| Suitable for rail mounting | Yes |
| Wall mounting/direct mounting | No |
| Front built-in possible | No |
| Rack-assembly possible | No |
| Suitable for safety functions | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Country of origin | Germany |