cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Eff.m.Darw for kont/startere (EU5C-SWD-PF1-1)

Eaton · Ireland · eaton.com
Part Number
EU5C-SWD-PF1-1  ·  HS 8538.90
Eff.m.Darw for kont/startere (EU5C-SWD-PF1-1)

Technical Specifications

Manufacturer part number (MPN)EU5C-SWD-PF1-1
EAN / GTIN4015081160495
Sales unitpcs
Eaton catalogue number116309
Depth125 mm
Height90 mm
Width35 mm
Weight0.109 kg
CertificationsUL Category Control No.: NKCR; IEC/EN 61131-2; CSA; CSA File No.: 2324643; UL; UL File No.: E29184; CSA Class No.: 3211-07; EN 50178
Catalog NotesSmartWire-DT power supply for additionally feeding the control voltage for motor starters and contactors, as well as for establishing emergency stop groups
Constant acceleration1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
Constant amplitude3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
Drop and topple50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max0.3 m
Mounting positionAs required
Shock resistance15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
Air pressure795 - 1080 hPa (operation)
Ambient operating temperature - max55 °C
Ambient storage temperature - max70 °C
Ambient operating temperature - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDry heat to IEC 60068-2-2; Damp heat, constant, to IEC 60068-2-3
Environmental conditionsCondensation: prevent with appropriate measures
Operating temperature - max55 °C
Operating temperature - min-25 °C
Relative humidity5 - 95 % (non-condensing, IEC/EN 60068-2-30)
Connection2 x SmartWire-DT blade terminal SWD4-8MF2
Connection to SmartWire-DTYes
Connection typeSWD: 2 x plug, 8-pole; Push in terminals, Supply voltage
ProtocolOther bus systems
Static heat dissipation, non-current-dependent Pvs1 W
Power lossNormally 1 W
Rated control supply voltage24 V DC (UAUX, -15 %/+20 %)
Rated operational voltageTypically UAUX -0.2 V (for 24 V DC slaves)
Short-circuit protectionNo, external fuse FAZ Z3, Supply voltage UAux
Supply current3 A, Imax, Supply voltage UAux
Supply voltage at DC - max28.8 VDC
Supply voltage at DC - min20.4 VDC
Air discharge8 kV, according to IEC 61131-2, level 3, ESD
Burst impulse2 kV, Supply cable, according to IEC/EN 61131-2, Level 3; 1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3
Contact discharge4 kV, according to IEC/EN 61131-2, Level 2, ESD
Electromagnetic fields3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008); 10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008); 1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008)
Radiated RFI10 V (IEC/EN 61131-2:2008, Level 3)
Radio interference classClass A (EN 55011)
Surge rating0.5 kV, Supply cables/CAN/DP bus cable, Surge power cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC
Electric connection typeFlat plug-in connection
FeaturesFieldbus connection over separate bus coupler possible; Fieldbus connection over separate bus coupler possible
Fitted withPower supply module
FunctionsFor feeding control voltage in order to connect additional motor starters and contactors to the SmartWire-DT ribbon cable; For the formation of emergency switching off groups for motor starters and contactors
Degree of protectionIP20
Mounting methodRail mounting possible; Top-hat rail fixing (according to IEC/EN 60715, 35 mm); Wall mounting/direct mounting
Overvoltage categoryII
Pollution degree2
Product categorySmartWire-DT accessories
Residual ripple≤ 5 % (input voltage)
Suitable asSegment module
Terminal capacity0.2 - 1.5 mm², solid; 24 - 16 AWG, solid or stranded; 0.25 - 1.5 mm², flexible with ferrule
Voltage typeDC
Explosion safety category for dustNone
Explosion safety category for gasNone
Potential isolationSupply voltage UAUX: no
Protection against polarity reversalYes; Yes, for supply voltage (Siemens MPI optional)
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Supply voltage DC20.4–28.8 V
Number of HW-interfaces other1
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsYes
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
System accessoryYes
Type of electric connectionFlat plug-in connection
With potential separationNo
With power supply moduleYes
Suitable as segment moduleYes
Remote moduleNo
Fieldbus connection over separate bus coupler possibleYes
Bus diagnosis possibleNo
Suitable for rail mountingYes
Wall mounting/direct mountingYes
Front built-in possibleNo
Rack-assembly possibleNo
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Country of originGermany

Properties

MOQ1

Cross-References