| Manufacturer part number (MPN) | 257901 |
| EAN / GTIN | 4015082579012 |
| Sales unit | pcs |
| Eaton catalogue number | 257901 |
| Depth | 100 mm |
| Height | 95 mm |
| Width | 30 mm |
| Weight | 0.135 kg |
| Certifications | CSA-C22.2 No. 0-M; EN 50178; UL; CSA; CSA Class No.: 2252-01; CSA File No.: 012528; CE; CSA-C22.2 No. 142-M; IEC/EN 61131-2; UL File No.: E135462; UL Category Control No.: NRAQ; UL508 |
| Catalog Notes | In these cases, the resistance value is 7FFFhex |
| Impact resistance | 500 g/⌀ 50 mm ±25 g |
| Shock resistance | 15 g, Mechanical, Shock duration 11 ms |
| Vibration resistance | 57 - 150 Hz ± 1.0 mm; 10 - 57 Hz, ± 0.075 mm |
| Ambient operating temperature - max | 55 °C |
| Ambient storage temperature - max | 70 °C |
| Ambient operating temperature - min | 0 °C |
| Ambient storage temperature - min | -25 °C |
| Operating temperature - max | 400 °C |
| Operating temperature - min | -20 °C |
| Connection type | Screened cable |
| Static heat dissipation, non-current-dependent Pvs | 4.8 W |
| Power loss | Max. 4.8 W |
| Power supply | 24 V DC (-15/+20 %), 100 mA |
| Rated operational voltage | 24 (12) V DC |
| Emitted interference | Class A (according to DIN/EN 55011/22) |
| Voltage dips | 10 ms |
| Electric connection type | Screw-/spring clamp connection |
| Features | Analog outputs configurable; Input, resistance thermometer; Analog inputs configurable |
| Functions | Linearization |
| Admissible range | 20.4 – 28.8 V (11.8 – 14.4 V), Power supply |
| Current consumption | 200 mA max., internal (5 V DC), Inputs |
| Degree of protection | IP20 |
| Overvoltage category | II |
| Pollution degree | 2 |
| Protection class | 1 |
| Repetition rate | 1 s |
| Residual ripple | ≤ 5 % |
| Resistance | Pt100 - IEC 751, Pt1000 (Platinum temperature resistance); Max 0.4 kΩ (4 channels, impedance) |
| Resolution | 15 Bit (signed, digital) |
| Type | Analog module |
| Used with | XC100/200 (expandable with up to 15 XI/OC modules) |
| Number of channels | 4, Input |
| Accuracy | 3 %, -50 to 400 °C (Pt100); 0.5 %, -20 to 40 °C (Pt100); 6 %, -50 to 400 °C (Pt100) |
| Input | 4 Inputs for temperature monitoring (Pt100/1000) |
| Number of inputs (analog) | 4 |
| Number of outputs (analog) | 0 |
| Temperature error | ≤ -25 °C or ≥ +45 °C = resistance value 7FFFFhex, Error detection -20 °C to 40 °C, Inputs; ≤ -60 °C or ≥ +410 °C = resistance value 7FFFFhex, Error detection -50 °C to 400 °C, Inputs |
| Explosion safety category for dust | None |
| Explosion safety category for gas | None |
| Potential isolation | Analog inputs: Opto-isolated; Analog outputs: no |
| Terminals | Optionally, screw terminals or spring-loaded terminals for digital/analog modules Plug-in terminal block |
| Number of analogue inputs | 4 |
| Analogue inputs configurable | Yes |
| Analogue outputs configurable | Yes |
| Input, current | No |
| Input, voltage | No |
| Input, resistor | No |
| Input, resistance thermometer | Yes |
| Input, thermocouple | No |
| Input signal, configurable | No |
| Resolution of the analogue inputs | 16 Bit |
| Output, current | No |
| Output, voltage | No |
| Output signal configurable | No |
| Type of electric connection | Screw-/spring clamp connection |
| Suitable for safety functions | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Country of origin | Japan |