cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Gw. SWD- Mod TCP and Eth IP (EU5C-SWD-EIP-MODTCP)

Eaton · Control & Automation · Fieldbus I/O · Ireland · eaton.com
Part Number
EU5C-SWD-EIP-MODTCP  ·  HS 8538.90
Gw. SWD- Mod TCP and Eth IP (EU5C-SWD-EIP-MODTCP)

Eaton EU5C-SWD-EIP-MODTCP.

Technical Specifications

Manufacturer part number (MPN)EU5C-SWD-EIP-MODTCP
EAN / GTIN4015081498901
Sales unitpcs
Eaton catalogue number153163
Depth127 mm
Height90 mm
Width35 mm
Weight0.162 kg
CompliancesEaton supports the product until its end of life
CertificationsCSA File No.: 2324643; UL File No.: E29184; CSA Class No.: 3211-07; IEC/EN 61131-2; UL Category Control No.: NKCR; CSA; EN 50178; UL
Constant acceleration1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
Constant amplitude3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
Drop and topple50 mm Drop height, Drop to IEC/EN 60068-2-31
Height of fall (IEC/EN 60068-2-32) - max0.3 m
Mounting positionAs required
Shock resistance15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
Air pressure795 - 1080 hPa (operation)
Ambient operating temperature - max55 °C
Ambient storage temperature - max70 °C
Ambient operating temperature - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingIn accordance with IEC 60068-2
Operating temperature - max55 °C
Operating temperature - min-25 °C
Relative humidity5 - 95 % (non-condensing, IEC/EN 60068-2-30)
AddressingAddress set automatically
Connection type2 x RJ45 (2-channel switch), Field bus interface; Push in terminals
Supply voltage; SWDPlug, 8-pole
InterfacesModule type: Ethernet IP/MODBUS-TCP Slave; Status display fieldbus interface for MS, Link status with Multi color LED
LED indicatorStatus indication of Supply voltage: LED; Status indication of SmartWire-DT network: Configurable green or red LED; Status indication of SmartWire-DT master: Green and red LEDs
Number of modules99 (SmartWire-DT)
ProtocolEthernet IP/MODBUS-TCP; MODBUS
StationIP, Station address, Fieldbus interface; SmartWire-DT master, SmartWire-DT network
Equipment heat dissipation, current-dependent Pvid3.8 W
Static heat dissipation, non-current-dependent Pvs1 W
Inrush current12.5 A (for 6 ms)
Power lossNormally 1 W
Rated control supply voltage24 V DC (UPOW, -15 %/+20 %); 24 V DC (UAUX, -15 %/+20 %)
Rated operational current (Ie)0.7 A
Rated operational voltageTypically UAUX -0.2 V (for 24 V DC slaves); 14.5 V (± 3 % - SmartWire-DT)
Short-circuit protectionNo, external fuse FAZ Z3, Supply voltage UAux; Yes, Short-circuit rating, SmartWire-DT supply voltage
Supply current - max0.7 mA
Supply voltage at DC - max28.8 V
Supply voltage at DC - min20.4 V
Air discharge8 kV, according to IEC 61131-2, level 3, ESD
Burst impulse1 kV; 1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3; 2 kV, Supply cable, according to IEC/EN 61131-2, Level 3
Contact discharge4 kV, according to IEC/EN 61131-2, Level 2, ESD
Electromagnetic fields10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008); 3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008); 1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008)
Radiated RFI10 V (IEC/EN 61131-2:2008, Level 3)
Radio interference classClass A (EN 55011)
Surge rating0.5 kV, Supply cable, Surge (IEC/EN 61131-2:2008, Level 1), EMC
Voltage dips≤ 10 ms, Bridging voltage dips
FeaturesOverload proof; Potential isolation (Fieldbus Interface)
FunctionsFor connection to the Ethernet-IP/MODBUS-TCP field bus
Operating modeAddress allocation via DIP switch/DHCP/BOOTP
Degree of protectionIP20
Mounting methodWall mounting/direct mounting; Rail mounting possible; Screw fixing using fixing brackets ZB4-101-GF1 (accessories); Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Overvoltage categoryII
Pollution degree2
Product categorySmartWire-DT coordinators
Repetition rate1 s
Residual ripple≤ 5 % (input voltage)
Suitable forSafety functions
Terminal capacity0.2 - 1.5 mm², solid; 24 - 16 AWG, solid or stranded; 0.25 - 1.5 mm², flexible with ferrule
Voltage typeDC
Explosion safety category for dustNone
Explosion safety category for gasNone
Potential isolationBetween UPow and 15 V SmartWire-DT supply voltage: no; Supply voltage UAUX: no
Protection against polarity reversalYes, for supply voltage (Siemens MPI optional); Yes
Number of HW-interfaces industrial Ethernet2
Number of HW-interfaces RS-2321
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Supply voltage DC20.4–28.8 V
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for SERCOSNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsNo
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard eGPRSNo
Radio standard GSMNo
Radio standard LTENo
Mobile communications standard 3G (UMTS)No
IO link masterNo
System accessoryYes
With potential separationNo
Fieldbus connection over separate bus coupler possibleNo
Suitable for rail mountingYes
Wall mounting/direct mountingYes
Front built-in possibleNo
Rack-assembly possibleNo
Suitable for safety functionsYes
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Country of originGermany

Properties

MOQ1

Cross-References

Attached Documents