| Manufacturer part number (MPN) | 4500803 |
| Sales unit | pcs |
| El-nummer (NO) | 4500803 |
| ETIM class | SC001417 |
| Power consumption | 1 W |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | Yes |
| Certified for UL hazardous location group A (acetylene) | Yes |
| Certified for UL hazardous location group B (hydrogen) | Yes |
| Certified for UL hazardous location group C (ethylene) | Yes |
| Certified for UL hazardous location group D (propane) | Yes |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location class I | Yes |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Supporting protocol for EtherCAT | No |
| Supply voltage DC | 20.4–28.8 V |
| Voltage type (supply voltage) | DC |
| Switching current | 5 A |
| With relay output | No |
| Number of HW-interfaces other | 1 |
| With optical interface | No |
| Supporting protocol for TCP/IP | Yes |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | Yes |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | No |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| IO link master | No |
| Redundancy | No |
| With display | No |
| Degree of protection (IP) | IP20 |
| Basic device | No |
| Expandable | Yes |
| Expansion device | Yes |
| With time switch clock | No |
| Suitable for rail mounting | Yes |
| Wall mounting/direct mounting | Yes |
| Front built-in possible | Yes |
| Rack-assembly possible | No |
| Suitable for safety functions | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Explosion safety category for gas | None |
| Explosion safety category for dust | None |
| Width | 36 mm |
| Height | 90 mm |
| Depth | 58 mm |
| Country of origin | Estonia |