| Manufacturer part number (MPN) | EASY-E4-DC-4PE1 |
| EAN / GTIN | 4015080892854 |
| Sales unit | pcs |
| Eaton catalogue number | 197224 |
| Depth | 58 mm |
| Height | 90 mm |
| Width | 36 mm |
| Weight | 0.1 kg |
| Drop and topple | 50 mm Drop height, Drop to IEC/EN 60068-2-31 |
| Height of fall (IEC/EN 60068-2-32) - max | 0.3 m |
| Mounting position | Horizontal; Vertical |
| Shock resistance | 15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 18 Impacts |
| Vibration resistance | 57 - 150 Hz, 2 g constant acceleration; 10 - 57 Hz, 0.15 mm constant amplitude; According to IEC/EN 60068-2-6 |
| Cable length | ≤ 30 m, unscreened, Analog inputs temperature resistance Pt100 or Ni1000 sensors |
| Air pressure | 795 - 1080 hPa (operation) |
| Ambient operating temperature - max | 55 °C |
| Ambient storage temperature - max | 70 °C |
| Ambient operating temperature - min | -25 °C |
| Ambient storage temperature - min | -40 °C |
| Environmental conditions | Condensation: prevent with appropriate measures; Clearance in air and creepage distances according to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
| Relative humidity | 5 - 95 % (IEC 60068-2-30, IEC 60068-2-78) |
| Connection type | Screw terminal |
| Static heat dissipation, non-current-dependent Pvs | 1 W |
| Heat dissipation | 3.4 W (at 24 V DC) |
| Inrush current | 12.5 A (for 6 ms) |
| Power consumption | 1 W |
| Power loss | 1 W |
| Rated operational voltage | 24 V DC (-15 %/+ 20 % - power supply); 20.4 - 28.8 V DC |
| Supply voltage at DC - max | 28.8 VDC |
| Supply voltage at DC - min | 20.4 VDC |
| Air discharge | 8 kV |
| Burst impulse | 2 kV, Signal cable; According to IEC/EN 61000-4-4; 2 kV, Supply cable |
| Contact discharge | 6 kV |
| Electromagnetic fields | 10 V/m at 0.8 - 1.0 GHz (according to IEC EN 61000-4-3); 1 V/m at 2.0 - 2.7 GHz (according to IEC EN 61000-4-3); 3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3) |
| Immunity to line-conducted interference | 10 V (according to IEC/EN 61000-4-6) |
| Radio interference class | Class B (EN 61000-6-3) |
| Surge rating | According to IEC/EN 61000-4-5, power pulses (Surge), EMC; 0.5 kV, Supply cables, symmetrical, EASY…DC, power pulses (Surge), EMC; 1 kV, Supply cables, asymmetrical, power pulses (Surge), EMC |
| Voltage dips | 20 ms; ≤ 10 ms, Bridging voltage dips |
| Features | Additional measurement aids: Filtering (software), smoothing of analog input signal (PT1 behavior), only with set sampling time, selectable per sensor: yes; Expandable; Expansion device; Measuring principle: Two or three wire per sensor, selectable by connection of sensor |
| Functions | Card diagnostic; Diagnostics below lower measurement range |
| Degree of protection | IP20 |
| Insulation resistance | According to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
| Mounting method | Rail mounting possible; Top-hat rail fixing (according to IEC/EN 60715, 35 mm); Wall mounting/direct mounting; Screw fixing using fixing brackets ZB4-101-GF1 (accessories); Front build in possible |
| Overvoltage category | III |
| Pollution degree | 2 |
| Product category | Control relays easyE4 |
| Protocol | TCP/IP; MODBUS |
| Residual ripple | ≤ 5 % |
| Resolution | 12 Bit (0- 4095, digital, scaling per sensor) |
| Software | EASYSOFT-SWLIC/easySoft |
| Type | easyE4 extension |
| Voltage type | DC |
| Input | Input type resistance sensor: Platinum sensor Pt100 (according to DIN EN 60751 |
| IEC 751); Input type resistance sensor | Nickel sensor Ni1000 (according to DIN 43760) |
| Input current | 40 mA |
| Number of inputs (analog) | 4 |
| Number of inputs (digital) | 0 |
| Number of outputs (analog) | 0 |
| Number of outputs (digital) | 0 |
| Explosion safety category for dust | None |
| Explosion safety category for gas | None |
| Potential isolation | Between Analog inputs PT100 or Ni1000 and Power supply: no; Between Analog inputs PT100 or Ni1000 and expansion units: yes; Between Analog inputs PT100 or Ni1000 and Inputs: no |
| Protection against polarity reversal | Yes, for supply voltage (Siemens MPI optional) |
| Short-circuit protection | ≥ 1A (T), Fuse, Power supply |
| Screwdriver size | 3.5 x 0.8 mm, Terminal screw |
| Terminal capacity | 0.2 - 2.5 mm² (22 - 12 AWG), flexible with ferrule; 0.2 - 4 mm² (AWG 22 - 12), solid |
| Tightening torque | 0.6 Nm, Screw terminals |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | Yes |
| Certified for UL hazardous location group A (acetylene) | Yes |
| Certified for UL hazardous location group B (hydrogen) | Yes |
| Certified for UL hazardous location group C (ethylene) | Yes |
| Certified for UL hazardous location group D (propane) | Yes |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location class I | Yes |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Supporting protocol for EtherCAT | No |
| Supply voltage DC | 20.4–28.8 V |
| Switching current | 0.5 A |
| Number of analogue inputs | 4 |
| With relay output | Yes |
| Number of HW-interfaces other | 2 |
| With optical interface | No |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | No |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| IO link master | No |
| Redundancy | No |
| With display | No |
| Basic device | No |
| Expandable | Yes |
| Expansion device | Yes |
| With time switch clock | No |
| Suitable for rail mounting | Yes |
| Wall mounting/direct mounting | Yes |
| Front built-in possible | Yes |
| Rack-assembly possible | No |
| Suitable for safety functions | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Country of origin | Germany |