cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Switch, systemprotection (PKE65/XTUCP-65)

Eaton · Electrical Components · Moulded Case Circuit Breakers · Ireland · eaton.com
Part Number
PKE65/XTUCP-65  ·  HS 8536.90
Switch, systemprotection (PKE65/XTUCP-65)

Technical Specifications

Manufacturer part number (MPN)PKE65/XTUCP-65
EAN / GTIN4015081654659
HS code8536.90
Sales unitpcs
Eaton catalogue number168974
Depth187 mm
Height162 mm
Width55 mm
Weight1.469 kg
CertificationsIEC/EN 60947; VDE 0660
Catalog NotesThis is a product for Environment A (Industrial). In environment B (household) this device may cause undesirable radio interference. In this case the user may be obliged to take appropriate measures.
Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AltitudeMax. 2000 m
Ambient operating temperature - max55 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78
ConnectionScrew terminals
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
Equipment heat dissipation, current-dependent Pvid21.6 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid7.2 W
Rated operational current for specified heat dissipation (In)65 A
Static heat dissipation, non-current-dependent Pvs0 W
Rated frequency - max60 Hz
Rated frequency - min50 Hz
Rated operational current (Ie)65 A
Rated operational voltage (Ue) - max690 V
Rated operational voltage (Ue) - min690 V
Rated uninterrupted current (Iu)65 A
Actuator typeTurn button
FeaturesComplete device with protection unit
Fitted withStandard knob
FunctionsLine and cable protection; Overload release; System protection
Number of polesThree-pole
Cut-out periods - min≤ 500 ms, main conducting paths, AC-4 cycle operation
Degree of protectionIP20; Terminals: IP00
Lifespan, electrical50,000 operations (at 400V, AC-3)
Lifespan, mechanical30,000 Operations (Main conducting paths)
Mounting MethodDIN rail (top hat rail) mounting optional
Operating frequency60 Operations/h
Overload release current setting - max65 A
Overload release current setting - min30 A
Overvoltage categoryIII
Pollution degree3
Product categoryCircuit-breaker PKE
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)6000 V AC
Resistance per pole1.6 mΩ
Suitable forDIN rail (top hat rail) mounting
Temperature compensation-5 - 40 °C to IEC/EN 60947, VDE 0660; -25 - 55 °C, Operating range
Short-circuit releaseTrip block adjustable 5 - 8 x Ir; Basic device fixed 15.5 x Iu, Trip Blocks; ± 20% tolerance, Trip blocks; Delayed approx. 60 ms, Trip blocks
Stripping length (main cable)14 mm
Terminal capacity (flexible with ferrule)2 x (0.75 - 25) mm², ferrule to DIN 46228; 1 x (0.75 - 35) mm², ferrule to DIN 46228
Terminal capacity (solid)2 x (0.75 - 16) mm²; 1 x (0.75 - 16) mm²
Tightening torque1 Nm, Screw terminals, Control circuit cables; 3.3 Nm, Screw terminals, Main cable

Properties

MOQ1

Cross-References

Attached Documents