Contactor 150A 24-27V DC (DILM150(RDC24))

Eaton · Electrical Components · Contactors · Ireland · eaton.com
Part Number
DILM150(RDC24)  ·  HS 8536.90
Contactor 150A 24-27V DC (DILM150(RDC24))

Eaton DILM150(RDC24) Contactor 3-pole, 24 VDC.

Technical Specifications

Manufacturer part number (MPN)DILM150(RDC24)
EAN / GTIN4015082395919
HS code8536.90
Sales unitpcs
Eaton catalogue number239591
Depth160 mm
Height170 mm
Width90 mm
Weight2.25 kg
CertificationsCE; CSA; CSA File No.: 012528; VDE 0660; UL File No.: E29096; IEC/EN 60947-4-1; CSA-C22.2 No. 60947-4-1-14; UL; UL 60947-4-1; UL Category Control No.: NLDX; IEC/EN 60947; CSA Class No.: 2411-03, 3211-04
Catalog NotesContacts according to EN 50012
AltitudeMax. 2000 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78
Connection to SmartWire-DTNo
Number of main contacts (normally open contact)3
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
Number of contacts (normally closed) as main contact0
Conventional thermal current Ith (1-pole, enclosed)360 A
Conventional thermal current Ith (3-pole, enclosed)144 A
Conventional thermal current Ith at 55°C (3-pole, open)170 A
Conventional thermal current Ith at 60°C (3-pole, open)160 A
Conventional thermal current Ith of main contacts (1-pole, open)400 A
Equipment heat dissipation, current-dependent Pvid32.1 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid10.7 W
Rated operational current for specified heat dissipation (In)150 A
Static heat dissipation, non-current-dependent Pvs1.9 W
Rated breaking capacity at 220/230 V1500 A
Rated breaking capacity at 380/400 V1500 A
Rated breaking capacity at 500 V1500 A
Rated breaking capacity at 660/690 V1200 A
Rated insulation voltage (Ui)690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)2100 A
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V190 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V150 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V150 A
Rated operational current (Ie) at AC-3, 440 V150 A
Rated operational current (Ie) at AC-3, 500 V150 A
Rated operational current (Ie) at AC-3, 660 V, 690 V100 A
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V65 A
Rated operational current (Ie) at AC-4, 440 V65 A
Rated operational current (Ie) at AC-4, 500 V65 A
Rated operational current (Ie) at AC-4, 660 V, 690 V50 A
Rated operational current (Ie) at DC-1, 110 V160 A
Rated operational current (Ie) at DC-1, 220 V90 A
Rated operational current (Ie) at DC-1, 60 V160 A
Rated operational power at AC-3, 240 V, 50 Hz52 kW
Rated operational power at AC-3, 380/400 V, 50 Hz75 kW
Rated operational power at AC-3, 415 V, 50 Hz91 kW
Rated operational power at AC-3, 440 V, 50 Hz95 kW
Rated operational power at AC-3, 500 V, 50 Hz110 kW
Rated operational power at AC-3, 690 V, 50 Hz96 kW
Rated operational power at AC-4, 220/230 V, 50 Hz20 kW
Rated operational power at AC-4, 240 V, 50 Hz22 kW
Rated operational power at AC-4, 415 V, 50 Hz39 kW
Rated operational power at AC-4, 440 V, 50 Hz41 kW
Rated operational power at AC-4, 500 V, 50 Hz47 kW
Rated operational power at AC-4, 660/690 V, 50 Hz48 kW
Rated operational voltage (Ue) at AC - max690 V
Emitted interferenceAccording to EN 60947-1
Interference immunityAccording to EN 60947-1
Fitted withSuppressor circuit in actuating electronics
Number of polesThree-pole
ApplicationContactors for Motors
ConnectionScrew terminals
Degree of protectionIP00
Lifespan, mechanical10,000,000 Operations (DC operated)
Operating frequency3600 mechanical Operations/h (DC operated)
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)8000 V AC
Residual current1 mA (with actuation of A1 - A2 by the electronics with "0" signal)
Resistance per pole0.6 mΩ
Suitable forAlso motors with efficiency class IE3
Utilization categoryAC-1: Non-inductive or slightly inductive loads, resistance furnaces; AC-4: Normal AC induction motors: starting, plugging, reversing, inching; AC-3: Normal AC induction motors: starting, switch off during running
Voltage typeDC
Frame sizeFS4
Arcing time15 ms
Drop-out voltage0.6 - 0.15 x UC, DC operated; At least smoothed two-phase bridge rectifier or three-phase rectifier
Duty factor100 %
Pick-up voltage0.7 - 1.2 V DC x Uc; 24 - 27 V DC (RDC 24)
Power consumption (pick-up) at DC149 W
Power consumption (sealing) at DC1.9 W
Rated control supply voltage (Us) at DC - max27 V
Rated control supply voltage (Us) at DC - min24 V
Switching time (DC operated, make contacts, closing delay) - max35 ms
Switching time (DC operated, make contacts, opening delay) - max30 ms
Assigned motor power at 115/120 V, 60 Hz, 1-phase10 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase50 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase30 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase60 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase125 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase125 HP
Safe isolation690 V AC, Between the contacts, According to EN 61140; 440 V AC, Between coil and contacts, According to EN 61140
Short-circuit current rating (basic rating)10 kA, 600 A max. fuse, SCCR (UL/CSA); 10 kA, 600 A max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)100 kA, 600 A CLASS J max. fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)100 kA, 600 A CLASS J max. fuse, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 400 V250 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V250 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V250 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V250 A gG/gL
Special purpose rating of definite purpose rating900 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA); 150 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Special purpose rating of elevator control75 HP, 480 V 60 Hz 3-ph, (UL/CSA); 100 HP, 600 V 60 Hz 3-ph, (UL/CSA); 92 A, 200 V 60 Hz 3-ph, (UL/CSA); 104 A, 240 V 60 Hz 3-ph, (UL/CSA); 96 A, 480 V 60 Hz 3-ph, (UL/CSA); 40 HP, 240 V 60 Hz 3-ph, (UL/CSA); 99 A, 600 V 60 Hz 3-ph, (UL/CSA); 30 HP, 200 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of refrigeration control (CSA only)90 A, FLA 600 V 60 Hz 3phase; (CSA); 540 A, LRA 600 V 60 Hz 3phase; (CSA); 90 A, FLA 480 V 60 Hz 3phase; (CSA); 540 A, LRA 480 V 60 Hz 3phase; (CSA)
Special purpose rating of resistance air heating160 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA); 160 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of tungsten incandescent lamps160 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA); 160 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of ballast electrical discharge lamps160 A (480V 60Hz 3phase, 277V 60Hz 1phase); 160 A (600V 60Hz 3phase, 347V 60Hz 1phase)
Switching capacity (main contacts, general use)225 A, Maximum motor rating (UL/CSA)
Screw sizeM10, Terminal screw, Main cables; 5 mm AF, Hexagon socket-head spanner, Terminal screw, Main cables; M3.5, Terminal screw, Control circuit cables
Screwdriver size0.8 x 5.5/1 x 6 mm, Terminal screw, Control circuit cables, Standard screwdriver; 2, Terminal screw, Control circuit cables, Pozidriv screwdriver
Stripping length (control circuit cable)10 mm
Stripping length (main cable)24 mm
Terminal capacity (copper band)2 x (6 x 16 x 0.8) mm (Number of segments x width x thickness), Main cables
Terminal capacity (solid)1 x (0.75 - 4) mm², Control circuit cables; 2 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (stranded)1 x (16 - 95) mm², Main cables; 2 x (16 - 70) mm², Main cables
Tightening torque1.2 Nm, Screw terminals, Control circuit cables; 14 Nm, Screw terminals, Main cables
Terminal capacity (flexible with ferrule)2 x (0.75 - 2.5) mm², Control circuit cables; 1 x (0.75 - 2.5) mm², Control circuit cables; 1 x (10 - 95) mm², Main cables; 2 x (10 - 70) mm², Main cables
Terminal capacity (solid/stranded AWG)Single 8…3/0, double 8…2/0, Main cables; 18 - 14, Control circuit cables

Properties

MOQ1

Cross-References

Attached Documents