cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Safety Relay ESR5-NZ-21-24VAC-DC

Eaton · Control & Automation · Relays & Timers · Ireland · eaton.com
Part Number
ESR5-NZ-21-24VAC-DC  ·  HS 8536.49
Safety Relay ESR5-NZ-21-24VAC-DC

Eaton ESR5-NZ-21-24VAC-DC Safety Relay, 24VDC/AC, 2 channels, 2 veier.

Technical Specifications

Manufacturer part number (MPN)ESR5-NZ-21-24VAC-DC
EAN / GTIN4015081168439
Sales unitpcs
Eaton catalogue number118703
Depth114.5 mm
Height99 mm
Width22.5 mm
Weight0.165 kg
Mounting positionAs required
Prooftest240 Months (High Demand)
Switching capacity5 A at 3600 O/h, AC-15 at 230 V, Outputs; In accordance with IEC 60947-5-1, Outputs; 0.4 W; 5 A at 3600 O/h, DC-13 at 24 V, Outputs
Vibration resistance10 - 150 Hz
Amplitude0.15 mm
Acceleration2 g, (IEC/EN 60068-2-6)
Air pressure795 - 1080 hPa (operation)
AltitudeMax. 2000 m
Ambient operating temperature - max55 °C
Ambient storage temperature - max70 °C
Ambient operating temperature - min-20 °C
Ambient storage temperature - min-40 °C
Climatic proofingDry heat to IEC 60068-2-2; Damp heat, constant, to IEC 60068-2-3
Environmental conditionsCondensation: Non-condensing; Clearance in air and creepage distances according to EN 50178, UL 508, CSA C22.2, No. 14-95
Operating temperature - max55 °C
Operating temperature - min-20 °C
Relative humidity< 75 %
Static heat dissipation, non-current-dependent Pvs5.16 W
Inrush current0.025 - 6 A
Power supply circuit3 W (AC operated 50/60 Hz); 1.5 W (DC operated)
Rated control supply voltage (Us) at AC
50 Hz - max24 V
Rated control supply voltage (Us) at AC
Rated control supply voltage (Us) at AC
60 Hz - max24 V
Rated control supply voltage (Us) at AC
60 Hz - min20.4 V
Rated control supply voltage (Us) at DC - max24 V
Rated insulation voltage (Ui)250 V
Rated operational voltage24 V AC/DC (power supply); 230 V AC; Approx. 24 V DC at input, starting and feedback circuit
Short-circuit current2.3 A, Input data
Short-circuit protectionShort-circuit proof, 24 V, Fuse for control circuit supply, Control circuit; Fuse 6 A gL/gG, For output circuits, External
Short-circuit protection rating6A gL/gG, NEOZED (N/C), Output fuse, External, Output data; 10A gL/gG, NEOZED (N/O), Output fuse, External, Output data
Electric connection typeScrew connection
FeaturesReinforced insulation; Automatic start; 2 Non-delayed enable current paths; Basic insulation; Monitoring of external contactor/expansion unit; Safe insulation
Fitted withApproval according to UL; Detachable clamps; Feedback circuit; Approval for TÜV
Functions2-channel; Two-hand function
MaterialContacts: silver tin oxide, gold plated (AgSnO2
0.2 µm Au); EnclosurePolyamide (PA), not reinforced
Connection typeM3 screw terminals
Current consumption60 mA, DC; 125 mA, AC
Degree of protectionIP20; Terminals: IP20; Installation location: ≥ IP54; Enclosure: IP20
Duty factor100 %
Emitted interferenceAccording to EN 61000-6-4
Interference immunityAccording to EN 61000-6-2
LED indicatorStatus indication of SmartWire-DT network: Green LED
Lifespan, mechanical10,000,000 Operations
Lifetime240 month
Mounting methodRail mounting possible; Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Mounting width22.5 mm
Overvoltage categoryIII
Pollution degree2
Power lossNormally 5.16 W
Product categoryElectronic safety relays
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)6000 V AC
Recovery time< 1000 ms
Safety parameter (EN ISO 13849-1)PL e, Performance level; 300,000 switching cycles, B10d; Cat. 4, Category
Safety parameter (IEC 62061)SILCL 3, Safety integrity level claim limit; EN 574 Type III C; SIL 3, Safety integrity level, In accordance with IEC 61508; Cat. 4, Category; 12.1 x 10-10, PFHd, Probability of failure per hour; SIL 3, Safety integrity level
Stop category (IEC 60204)0
Suitable forSafety functions; Module used to safely interrupt electrical circuits; Safety relay for monitoring two-hand control per EN 574 Type IIIC and protective door switches
Switching frequencyMax. 0.5 Hz, Input data
TypeFeedback circuit Protective door
Voltage typeAC/DC
Input< 500 ms, Simultaneity for inputs 1/2
Nominal current60 A
Number of inputs2-channel
Number of outputs (safety related, delayed) with contact0
Number of outputs (safety related, undelayed) with contact2
Number of outputs (signaling function, delayed) with contact0
Number of outputs (signaling function, undelayed) with contact1
Permissible total cable resistance50 Ω (input and starting circuits for UN)
Pick-up time50 ms typ. (at Uₑ in automatic mode); 50 ms typ. (K1, K2 - for UN automatic mode); 50 ms typ. (K1, K2 - for UN manual operation); 50 ms typ. (at Uₑ in manual mode)
Quadratic summation current72 A² (ITH² = I1² + I2²)
Reset timeNormally 20 ms
Resistance22 Ω (impedance)
Switching voltage250 V
Uninterrupted current6 A N/O, Limiting continuous current; 6 A N/C, Limiting continuous current
Screwdriver size3.5 x 0.6 mm, Terminal screw; 2, Terminal screw, Pozidriv screwdriver
Stripping length (main cable)7 mm
Terminal capacity1 x (0.2 – 2.5) mm², solid; 2 x (0.2 – 1) mm², solid; 2 x (0.25 – 1) mm², flexible with ferrule; 24 - 12 AWG, solid or stranded; 1 x (0.25 – 2.5) mm², flexible with ferrule
Tightening torque0.6 Nm, Screw terminals
Suitable for safety functionsYes
With approval according to ULYes
Control voltage 124 V
Control voltage 224 V
Type of control voltage 1AC/DC
Type of control voltage 2AC/DC
With detachable clampsYes
With start inputNo
With feedback circuitYes
Number of outputs, safety related, undelayed, with contact2
Type class for safety demands according to EN 574Type III C
Suitable for rail mountingYes
With approval for BG BIANo
Rated switch current5 A
Performance level according to EN ISO 13849-1Level e
Supply voltage AC 50 Hz24 V
Supply voltage AC 60 Hz24 V
Supply voltage DC24 V
Operating voltage AC 50 Hz24 V
Operating voltage AC 60 Hz24 V
Operating voltage DC24 V
Voltage type for actuatingAC/DC
SIL according to IEC 615083
Country of originGermany

Properties

MOQ1

Cross-References