CONTACTOR,40A AC-3, AC Coil (DILM40(24V50HZ))

Eaton · Electrical Components · Contactors · Ireland · eaton.com
Part Number
DILM40(24V50HZ)  ·  HS 8536.90
CONTACTOR,40A AC-3, AC Coil (DILM40(24V50HZ))

Eaton DILM40(24V50HZ) Contactor 3-pole, 24 VAC incl. 1NO.

Technical Specifications

Manufacturer part number (MPN)DILM40(24V50HZ)
EAN / GTIN4015082777531
HS code8536.90
Sales unitpcs
Eaton catalogue number277753
Depth132.1 mm
Height115 mm
Width55 mm
Weight0.872 kg
CompliancesCE Marked
CertificationsCSA Std. C22.2 No. 14-05; EN 60947-4-1; IEC 60947-4-1; UL 508; VDE; IEC/EN 60947-4-1; UL 60947-4-1; CSA-C22.2 No. 60947-4-1-14; UL Category Control No.: NLDX; IEC/EN 60947; VDE 0660; CE; CSA; UL File No.: E29096; UL; CSA File No.: 012528; CSA Class No.: 2411-03, 3211-04
Catalog NotesContacts according to EN 50012
AltitudeMax. 2000 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30
Connection to SmartWire-DTNo
Number of main contacts (normally open contact)3
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
Number of contacts (normally closed) as main contact0
Conventional thermal current Ith (1-pole, enclosed)112 A
Conventional thermal current Ith (3-pole, enclosed)45 A
Conventional thermal current Ith at 55°C (3-pole, open)55 A
Conventional thermal current Ith at 60°C (3-pole, open)50 A
Conventional thermal current Ith of main contacts (1-pole, open)125 A
Equipment heat dissipation, current-dependent Pvid6.6 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid2.2 W
Rated operational current for specified heat dissipation (In)40 A
Static heat dissipation, non-current-dependent Pvs4.1 W
Rated breaking capacity at 220/230 V400 A
Rated breaking capacity at 380/400 V400 A
Rated breaking capacity at 500 V400 A
Rated breaking capacity at 660/690 V250 A
Rated insulation voltage (Ui)690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)560 A
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V60 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V40 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V40 A
Rated operational current (Ie) at AC-3, 440 V40 A
Rated operational current (Ie) at AC-3, 500 V40 A
Rated operational current (Ie) at AC-3, 660 V, 690 V25 A
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V18 A
Rated operational current (Ie) at AC-4, 440 V18 A
Rated operational current (Ie) at AC-4, 500 V18 A
Rated operational current (Ie) at AC-4, 660 V, 690 V14 A
Rated operational current (Ie) at DC-1, 110 V50 A
Rated operational current (Ie) at DC-1, 220 V45 A
Rated operational current (Ie) at DC-1, 60 V50 A
Rated operational power at AC-3, 240 V, 50 Hz13.5 kW
Rated operational power at AC-3, 380/400 V, 50 Hz18.5 kW
Rated operational power at AC-3, 415 V, 50 Hz24 kW
Rated operational power at AC-3, 440 V, 50 Hz25 kW
Rated operational power at AC-3, 500 V, 50 Hz28 kW
Rated operational power at AC-3, 690 V, 50 Hz23 kW
Rated operational power at AC-4, 220/230 V, 50 Hz5 kW
Rated operational power at AC-4, 240 V, 50 Hz5.5 kW
Rated operational power at AC-4, 415 V, 50 Hz9.5 kW
Rated operational power at AC-4, 440 V, 50 Hz10 kW
Rated operational power at AC-4, 500 V, 50 Hz11 kW
Rated operational power at AC-4, 660/690 V, 50 Hz12 kW
Rated operational voltage (Ue) at AC - max690 V
Emitted interferenceAccording to EN 60947-1
Interference immunityAccording to EN 60947-1
Number of polesThree-pole
ApplicationContactors for Motors
ConnectionScrew terminals
Degree of protectionIP00
Lifespan, mechanical10,000,000 Operations (AC operated)
Operating frequency5000 mechanical Operations/h (AC operated)
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)8000 V AC
Resistance per pole1.9 mΩ
Suitable forAlso motors with efficiency class IE3
Utilization categoryAC-4: Normal AC induction motors: starting, plugging, reversing, inching; AC-1: Non-inductive or slightly inductive loads, resistance furnaces; AC-3: Normal AC induction motors: starting, switch off during running
Voltage typeAC
Frame sizeFS3
Arcing time10 ms
Drop-out voltageAC operated: 0.6 - 0.3 x UC, AC operated
Duty factor100 %
Pick-up voltage0.8 - 1.1 V AC x Uc
Power consumption, pick-up, 50 Hz149 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Power consumption, pick-up, 60 Hz178 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Power consumption, sealing, 50 Hz4.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz; 16 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Power consumption, sealing, 60 Hz4.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz; 19 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Rated control supply voltage (Us) at AC, 50 Hz - max24 V
Rated control supply voltage (Us) at AC, 50 Hz - min24 V
Switching time (AC operated, make contacts, closing delay) - max18 ms
Switching time (AC operated, make contacts, closing delay) - min12 ms
Switching time (AC operated, make contacts, opening delay) - max13 ms
Switching time (AC operated, make contacts, opening delay) - min8 ms
Assigned motor power at 115/120 V, 60 Hz, 1-phase3 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase10 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase7.5 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase15 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase30 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase40 HP
Safe isolation440 V AC, Between coil and contacts, According to EN 61140; 440 V AC, Between the contacts, According to EN 61140
Short-circuit current rating (basic rating)5 kA, 250 A max. fuse, SCCR (UL/CSA); 5 kA, 250 A max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)100 kA, 150 A CLASS J max. fuse, SCCR (UL/CSA); 65 kA, 100 A max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)100 kA, 150 A CLASS J max. fuse, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 400 V125 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V80 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V63 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V50 A gG/gL
Special purpose rating of elevator control32 A, 600 V 60 Hz 3-ph, (UL/CSA); 10 HP, 240 V 60 Hz 3-ph, (UL/CSA); 7.5 HP, 200 V 60 Hz 3-ph, (UL/CSA); 25 HP, 480 V 60 Hz 3-ph, (UL/CSA); 30 HP, 600 V 60 Hz 3-ph, (UL/CSA); 28 A, 240 V 60 Hz 3-ph, (UL/CSA); 25.3 A, 200 V 60 Hz 3-ph, (UL/CSA); 34 A, 480 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of resistance air heating79 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA); 79 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of tungsten incandescent lamps74 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA); 74 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of ballast electrical discharge lamps79 A (480V 60Hz 3phase, 277V 60Hz 1phase); 79 A (600V 60Hz 3phase, 347V 60Hz 1phase)
Switching capacity (main contacts, general use)63 A, Maximum motor rating (UL/CSA)
Screw sizeM6, Terminal screw, Main cables; M3.5, Terminal screw, Control circuit cables
Screwdriver size0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver; 2, Terminal screw, Pozidriv screwdriver
Stripping length (control circuit cable)10 mm
Stripping length (main cable)14 mm
Terminal capacity (copper band)2 x (6 x 9 x 0.8) mm (Number of segments x width x thickness), Main cables
Terminal capacity (solid)1 x (0.75 - 16) mm², Main cables; 2 x (0.75 - 16) mm², Main cables; 1 x (0.75 - 4) mm², Control circuit cables; 2 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (stranded)1 x (16 - 50) mm², Main cables; 2 x (16 - 35) mm², Main cables
Tightening torque3.3 Nm, Screw terminals, Main cables; 1.2 Nm, Screw terminals, Control circuit cables
Terminal capacity (flexible with ferrule)2 x (0.75 - 25) mm², Main cables; 2 x (0.75 - 2.5) mm², Control circuit cables; 1 x (0.75 - 35) mm², Main cables; 1 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid/stranded AWG)18 - 14, Control circuit cables; Single 14 - 1, double 14 - 2, Main cables

Properties

MOQ1

Cross-References

Attached Documents