cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Temperature monitoring relay (EMR6-T100-A-1)

Eaton · Control & Automation · Monitoring Relays · Ireland · eaton.com
Part Number
EMR6-T100-A-1  ·  HS 8536.49
Temperature monitoring relay (EMR6-T100-A-1)

Technical Specifications

Manufacturer part number (MPN)EMR6-T100-A-1
EAN / GTIN4015081788231
Sales unitpcs
Eaton catalogue number184787
Depth103.7 mm
Height85.6 mm
Width22.5 mm
Weight0.151 kg
CertificationsUL 508; CCC; CE; CSA-C22.2 No. 14; EAC; GL
Ambient operating temperature - max60 °C
Ambient storage temperature - max85 °C
Ambient operating temperature - min-40 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30
Air dischargeAccording to IEC/EN 61000-4-2 level 3
Burst impulseAccording to IEC/EN 61000-4-4, level 3
Contact dischargeAccording to IEC/EN 61000-4-2, Level 3
Electromagnetic compatibilityAccording to IEC/EN 60947-6-2
Immunity to line-conducted interferenceLevel 3 (according to IEC/EN 61000-4-6)
Immunity to radiationLevel 3 (according to IEC/EN 61000-4-3)
Surge ratingAccording to IEC/EN 61000-4-5 Level 4
Electric connection typeScrew connection
Monitoring functionSuperheating and supercooling (window); Supercooling; Overheating
Temperature measuring range - max100 °C
Temperature measuring range - min0 °C
Degree of protectionTerminals: IP20; Enclosure: IP50
LED indicatorOther states depending on fault (see IL): Measured value; Status indication of Supply voltage: Green, solid light
Lifespan, mechanical30,000,000 Operations
Mounting positionAs required
Overvoltage categoryIII
Pollution degree3
Product categoryEMR Measuring and monitoring relays
Rated impulse withstand voltage (Uimp)4000 V AC
Shock resistanceClass 2
TypeTemperature monitor
Voltage typeAC/DC
Hysteresis2 - 20 %
Duty factor100 %, Power supply
Power consumption2.9 VA
Rated control supply voltage (Us) at AC, 50 Hz - max240 V
Rated control supply voltage (Us) at AC, 50 Hz - min24 V
Rated control supply voltage (Us) at AC, 60 Hz - max240 V
Rated control supply voltage (Us) at AC, 60 Hz - min24 V
Rated control supply voltage (Us) at DC - max240 V
Rated control supply voltage (Us) at DC - min24 V
Rated frequency - max60 Hz
Rated frequency - min50 Hz
Supply voltage24 - 240 V DC; 24 - 240 V AC, 50/60 Hz
Voltage tolerance0.85 x Uc; 1.1 x Uc
Lifespan, electrical100,000 Operation (at 230 V, AC-12, 4 A)
Number of contacts (change-over contacts)2
Number of contacts (normally closed contacts)0
Number of contacts (normally open contacts)0
Connection typeSnap fixing, top-hat rail IEC/EN 60715
Screwdriver size4 x 0.8 mm, Terminal screw
Terminal capacity2 x (0.5-1.5) mm², (2 x (18-16) AWG), flexible with ferrule; 1 x (0.5-2.5) mm², (1 x (18-14) AWG), solid
Tightening torqueMin. 0.5 Nm, Screw terminals; Max. 0.8 Nm, Screw terminals
Operating voltage AC 50 Hz24–240 V
Operating voltage AC 60 Hz24–240 V
Operating voltage DC24–240 V
Supply voltage AC 50 Hz24–240 V
Supply voltage AC 60 Hz24–240 V
Supply voltage DC24–240 V
Rated switch current4 A
Connection type auxiliary circuitScrew connection
Type of electric connectionScrew connection
Rated control supply voltage AC 50 Hz24–240 V
Rated control supply voltage AC 60 Hz24–240 V
Rated control supply voltage DC24–240 V
Voltage type for actuatingAC/DC
With detachable clampsNo
Number of measuring circuits1
Error registration possibleNo
External reset possibleNo
Number of contacts as change-over contact2
Temperature measuring range0–100 °C
Country of originGermany

Properties

MOQ1

Cross-References

Attached Documents