| Manufacturer part number (MPN) | FAZ-XHIN11 |
| EAN / GTIN | 4015082860547 |
| Sales unit | pcs |
| Package quantity | 10 pcs |
| Eaton catalogue number | 286054 |
| Depth | 80 mm |
| Height | 75.5 mm |
| Width | 8.8 mm |
| Weight | 0.046 kg |
| Compliances | RoHS conform |
| Certifications | UL (File No. E177451); North America (UL listed, certified by UL for use in Canada); IEC/EN 60898; CSA (Class No. 3215-30); UL 1077; CE marking; UL (Category Control Number QVNU2, QVNU9); IEC/EN 60947-2; CSA-C22.2 No. 235; EN45545-2; IEC 61373 |
| Catalog Notes | &1NC |
| Used with | Accessory; Accessory for miniature circuit breaker |
| Voltage rating | 250 V AC |
| Amperage Rating | 6 A |
| Accessory/spare part type | Auxiliary contacts |
| Degree of protection | UL/CSA Type: -; IP40; IP20 (IEC) |
| Frame | Standard front dimension: 45 mm |
| Frequency rating | 50 Hz / 60 Hz |
| Rated impulse withstand voltage (Uimp) | 2.5 kV |
| Mounting method | Max. 2 x on MCB |
| Additional equipment required | Auxiliary switch |
| Admissible back-up fuse - max | 6 A gL |
| Terminal protection | Protection against electric shock to IEC 536 |
| Terminal type | Lift terminals |
| Ambient operating temperature - max | 40 °C |
| Ambient operating temperature - min | -5 °C |
| Assembly width | 0.5 |
| Conventional thermal current Ith of auxiliary contacts (1-pole, open) | 6 A |
| Enclosure width | 80 mm |
| Number of contacts (change-over contacts) | 0 |
| Number of contacts (normally closed contacts) | 1 |
| Number of contacts (normally open contacts) | 1 |
| Number of poles at main contact unit - max | 2 |
| Number of switches (fault signal) | 0 |
| Rated conditional short-circuit current (Iq) with 6 a back-up fuse | 1 kA |
| Rated insulation voltage (Ui) | 250 VAC |
| Voltage type | AC |
| Functions | Auxiliary switch |
| Contact function | 1 NO + 1 NC |
| Device fitting | Universal |
| Type | Accessory Accessory for miniature circuit breaker |
| Mounting width | 8.8 mm (0.5 space units) |
| Rated operational voltage (Ue) - max | 230 V |
| Rated switch current | 3 A |
| Voltage rating per contact - min | 5 VDC |
| Rated operational current | 0.5 A (110 V DC-12); 2 A (250 V AC-15); 3 A (250 V AC-13) |
| Terminal capacity (cable) | 0.5 mm² - 2.5 mm² |
| Terminal capacity (solid wire) | 0.5 mm² - 2.5 mm² |
| Rated voltage | 230 V |
| Installed at the factory | No |
| Width in number of modular spacings | 0.5 |
| Additional equipment | Auxiliary switch |
| Voltage type for actuating | AC |
| Number of contacts as normally closed contact | 1 |
| Number of contacts as normally open contact | 1 |
| With auto test for earth leakage function | No |
| Suitable for max. number of poles main contact unit (total) | 2 |
| Country of origin | Serbia |