Earth-fault RCD 16A 3P+N/C A 30MA (MRB6-16/3N/C/003-A)

Eaton · Electrical Components · RCDs & RCBOs · Ireland · eaton.com
Part Number
mRB6-16/3N/C/003-A  ·  HS 8536.90
Earth-fault RCD 16A 3P+N/C A 30MA (MRB6-16/3N/C/003-A)

Eaton mRB6-16/3N/C/003-A 16 Ampèr 4 pole/4modules RCBO.Trip indicator white/blue. C-characteristic.

Technical Specifications

Manufacturer part number (MPN)mRB6-16/3N/C/003-A
EAN / GTIN4015081184903
HS code8536.90
Sales unitpcs
Package quantity30 pcs
Eaton catalogue number120660
Depth80 mm
Height75.5 mm
Width70 mm
Weight0.445 kg
CompliancesRoHS conform
CertificationsCE
Current limiting class3
FeaturesConcurrently switching N-neutral
StandardsIEC/EN 61009
ApplicationSwitchgear for residential and commercial applications
Basic functionCombined RCD/MCB devices
Fault current rating0.03 A
Number of polesThree-pole + N
Number of poles (protected)4
Number of poles (total)4
Product applicationSwitchgear for industrial and advanced commercial applications
Product rangemRB6
Rated current16 A
Rated current of product range6 - 25 Ampere
Release characteristicC
Sensitivity typeType A, pulse-current sensitive
Tripping characteristicC
TypeRCBO
Ambient operating temperature - max40 °C
Ambient operating temperature - min-25 °C
Equipment heat dissipation, current-dependent10.9 W
Heat dissipation capacity0 W
Heat dissipation per pole, current-dependent0 W
Rated operational current for specified heat dissipation (In)16 A
Static heat dissipation, non-current-dependent0 W
Back-up fuse100 Ampere gL
Disconnection characteristicUndelayed
Frequency rating50 Hz
Impulse withstand currentPartly surge-proof, 250 A
Leakage current typeA
Pollution degree2
Rated fault currents of product range30, 100, 300 MilliAmpere
Rated impulse withstand voltage (Uimp)4 kV
Rated insulation voltage (Ui)500 V
Rated non-tripping current0.5 x I∆n
Rated operational voltage (Ue) - max400 V
Rated short-circuit breaking capacity (EN 60947-2)6 kA
Rated short-circuit breaking capacity (EN 61009-1)6 kA
Rated short-circuit breaking capacity (EN 61009)6 kA
Rated switching capacity6 kA
Rated switching capacity (IEC/EN 60947-2)6 kA
Rated switching capacity (IEC/EN 61009)6 kA
Selectivity class3
Surge current capacity0.25 kA
TrippingNon-delayed
Voltage rating400 V
Voltage rating at AC230 V / 400 V
Voltage typeAC
Built-in depth70 mm
Climatic proofingIEC 68-2: 25 °C - 55 °C at 90 % - 95 % humidity
Connectable conductor cross section (multi-wired) - max25 mm²
Connectable conductor cross section (multi-wired) - min1 mm²
Connectable conductor cross section (solid-core) - max25 mm²
Connectable conductor cross section (solid-core) - min1 mm²
Degree of protectionIP20
Degree of protection (built in)IP40
Device height80 mm
Frame45 mm
Material thickness2 mm
Mounting MethodDIN rail
Mounting styleTri-stable slide catch - enables removal from existing busbar combination
Solid terminal capacities1 - 25 Square Millimeter
Terminal protectionBusbar tag shroud to VBG4
Terminals (top and bottom)Twin-purpose
Width in number of modular spacings4

Properties

MOQ1

Cross-References