cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-06
sales@cballast.com
cballast.com

Eaton FAZ-OV63/3 Miniature Circuit Breaker — 3P, OV, 63 A, 15 kA

Eaton · Electrical Components · Miniature Circuit Breakers · Ireland · eaton.com
Part Number
FAZ-OV63/3  ·  HS 8536.20
Eaton FAZ-OV63/3 Miniature Circuit Breaker — 3P, OV, 63 A, 15 kA

Eaton FAZ-OV63/3 miniature circuit breaker (MCB) from the xEffect FAZ range. 3-pole, rated current In = 63 A, thermomagnetic overload and short-circuit release (Eaton 'OV' overload-protection designation). Rated ultimate short-circuit breaking capacity Icu = 15 kA to IEC/EN 60947-2; rated operational voltage Ue 230/400 V AC. DIN-rail (35 mm) modular device for overload and short-circuit protection of cables and equipment. Conforms to IEC/EN 60947-2. Eaton type FAZ-OV63/3, EAN 9010238117914, El-nr (NO) 1624153.

Technical Specifications

ManufacturerEaton
Product familyxEffect FAZ
Type designationFAZ-OV63/3
Manufacturer part number (MPN)FAZ-OV63/3
EAN / GTIN9010238117914
El-nummer (NO)1624153
Poles3P
Releasethermomagnetic (overload + short-circuit)
Rated current In63 A
Rated ultimate breaking capacity Icu15 kA
Rated operational voltage Ue230/400 V AC
MountingDIN rail (35 mm)
StandardIEC/EN 60947-2
HS code8536.20
Sales unitpcs
Eaton catalogue number300360
Depth72.6 mm
Height80 mm
Width53.1 mm
Weight0.369 kg
CompliancesRoHS conform
Current limiting class3
FeaturesAdditional equipment possible
Suitable forFlush-mounted installation
Amperage Rating63 A
Number of poles (protected)3
Number of poles (total)3
Release characteristicOther
Ambient operating temperature - max55 °C
Ambient operating temperature - min-20 °C
Frequency rating - max60 Hz
Frequency rating - min50 Hz
Overvoltage categoryIII
Pollution degree2
Rated impulse withstand voltage (Uimp)4 kV
Rated insulation voltage (Ui)440 V
Rated operational voltage (Ue) - max230 V
Rated short-circuit breaking capacity (IEC/EN 60898-1) - Icn at 230 V10 kA
Rated short-circuit breaking capacity (IEC/EN 60898-1)- Icn at 400 V10 kA
Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 230 V15 kA
Rated short-circuit breaking capacity (IEC 60947-2)- Icu at 400 V15 kA
Voltage typeAC
Built-in depth60 mm
Connectable conductor cross section (multi-wired) - max16 mm²
Connectable conductor cross section (multi-wired) - min2 mm²
Connectable conductor cross section (solid-core) - max35 mm²
Connectable conductor cross section (solid-core) - min1.5 mm²
Degree of protectionIP20
Width in number of modular spacings3
Document NameDescription Action

Properties

Primary standardIEC/EN 60947-2
MOQ1

Standards

Cross-References

Attached Documents