cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Danfoss RT110 Pressure Switch 0.2 to 3 bar SPDT Manual Min (017-511066)

Danfoss · Sensors & Instrumentation · Pressure Sensors · Denmark · danfoss.com
Part Number
017-511066  ·  HS 9032.20
Danfoss RT110 Pressure Switch 0.2 to 3 bar SPDT Manual Min (017-511066)

Danfoss RT110 mechanical pressure switch with bellows sensing element, single-pole double-throw (SPDT) contact and manual min reset. Regulating range 0.2 to 3 bar; G 3/8 in male pressure connection (ISO 228-1); enclosure IP54. Danfoss code number 017-511066.

Technical Specifications

BrandDanfoss
ModelRT110 pressure switch
Code number017-511066
Regulating range (Pe)0.2 to 3 bar
Maximum working pressure7 bar
Contact functionSPDT (single-pole double-throw)
ResetManual Min
Differential0.08 bar (fixed)
Pressure sensing elementbellows
Pressure connectionG 3/8 in male (ISO 228-1)
EnclosureIP54
Ambient temperature range-50 to +70 degC (-58 to +158 degF)
Cable entry2 x Pg 13.5
Contact ratingAC15=3 A at 400 V; AC1=10 A at 400 V; AC3=4 A at 400 V; DC13=12 W at 220 V; LR=28 A at 400 V
StandardsEN 60947-4, EN 60947-5
ApprovalsCE, EAC, DNV, LR, BV, GL
Product typeRT110
Product groupSwitches and thermostats
Max. test pressure116.0 psig
Max. test pressure Pe8.0 bar
Max. working pressure7.0 bar
Fluid Group1
PED categoryIV
CE markYes
REACH candidate-list substancesLead (CAS no. 7439-92-1)
Net weight0.89 kg
EAN5702423119608
Contact rating @ 250K cyclesAC15=1 A, 400 V; AC1=10 A, 400 V; AC3=2 A, 400 V; DC13=12 W, 220 V; LR=14 A, 400 V
EEE category5 small equipment (any external dimension < 50 cm)
Electrical conn
Male/FemaleFemale
Electrical connectionScrewed cable entry
Electrical connection size2xPg 13.5
Electrical connection standardDIN 40430
Electrical spec. standardEN 60947-4/-5
EN 60947 electrical propertiesInsulation: 400V; Pollution degree: 3; Rated impulse voltage: 4 kV; Short circuit prot, fuse: 10A
EN 60947 wiring propertiesFlex, ferrules: 0.2-1.5 mm2; Flex, no ferrules: 0.2-2.5 mm2; Solid/stranded: 0.2-2.5 mm2
Enclosure rating IPIP54
In scope of WEEEYes
Pressure connection size3/8
Pressure connection standardISO 228-1

Properties

MaterialBellows sensing element
Pressure rating7 bar
Temperature range-50 to +70 degC
IP ratingIP54
Primary standardEN 60947-5
Thread standardISO 228-1
MOQ1

Compatibility

Danfoss RT mechanical pressure switches interchange with same code-number variants at equal regulating range, contact function, reset type and pressure connection. Confirm range, differential and connection before ordering.

Standards

Approvals

Attached Documents