cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Danfoss KP34 pressure switch, 0.14 to 1.07 bar, manual (max) reset, SPDT, G1/2

Danfoss · Sensors & Instrumentation · Pressure Switches · Denmark · danfoss.com
Part Number
060-216366  ·  HS 9026.20
Danfoss KP34 pressure switch, 0.14 to 1.07 bar, manual (max) reset, SPDT, G1/2

Danfoss KP34 low-pressure switch (code 060-216366). Regulating range 0.14 to 1.07 bar, fixed differential 0.21 bar, manual reset on max, SPDT snap-action contact. G1/2 (ISO 228-1) male connection, IP30 enclosure, ambient -40 to +65 °C. Max working pressure 4 bar, max test pressure 6 bar. Manual reset locks out on over-pressure for safety limiting.

Technical Specifications

TypeKP34 low-pressure switch
Code number060-216366
Regulating range0.14 to 1.07 bar
Differential0.21 bar (fixed)
Max working pressure (PB)4 bar
Max test pressure (Pe)6 bar
Resetmanual (max), lock-out on over-pressure
Contact systemSPDT (single-pole double-throw)
Contact load16 A resirigide, single phase (120 Vac: 16 FLA / 96 LRA / 3 A pilot duty)
ConnectionG1/2 (ISO 228-1) male
EnclosureIP30
Ambient temperature-40 to +65 °C (80 °C max 120 min)
Pressure elementbellows
Product groupSwitches and thermostats
Max. test pressure87.0 psig
Max. test pressure Pe6.0 bar
ApprovalCCC; CE; EAC; LLC CDC EURO-TYSK; LVD; RINA; RMRS; RoHS China; c UL us UL353, CS C22.2; c UL us UL873, CS C22.2
UL approval file nameE31024; MH27572
UL approved refrigerantsR1234yf; R1234ze(E); R452B; R454A; R454C; R455A
UL markYes
CE markYes
REACH candidate-list substancesLead (CAS no. 7439-92-1); Cadmium oxide (CAS no.1306-19-0)
Net weight0.476 kg
EAN5702423263769
Amb
Temp
Note80 °C/176 °F for max 120 min
Contact functionSPDT
Contact rating120Vac,16FLA,96LRA,3APilotDuty; 16 A resistive, single phase; 240 V AC, 8 FLA, 48 LRA; 240V dc,12W pilot duty(0.05 A); 8 A resistive, single phase
EEE category5 small equipment (any external dimension < 50 cm)
Electrical connectionRubber cable gland
Electrical connection size6-14 mm
EN 60947 electrical propertiesInsulation: 400V; Pollution degree: 3; Rated impulse voltage: 4 kV; Short circuit prot, fuse: 16A
EN 60947 wiring propertiesFlex, ferrules: 0.5-1.5 mm2; Flex, no ferrules: 0.7-2.5 mm2; Solid/stranded: 0.75-2.5 mm2
Enclosure rating IPIP30
Enclosure rating Nema (~)1
In scope of WEEEYes
Pressure connection size1/2
Pressure connection standardISO 228-1
Pressure connection typeG
Pressure Male/FemaleMale
Pressure sensing elementBellows

Properties

MaterialSteel/zinc-plated housing; bellows pressure element
Pressure ratingPB 4 bar; max test 6 bar
Temperature range-40 to +65 °C (80 °C max 120 min)
IP ratingIP30
Thread standardG1/2 (ISO 228-1) male
MOQ1

Compatibility

Low-pressure safety switch with manual reset lock-out on over-pressure. SPDT contact wired NO or NC. G1/2 (ISO 228-1) male connection. Verify range/differential against the set point before ordering.

Standards

Approvals

Attached Documents