Danfoss DST P310 pressure transmitter, code 076G1020. Measuring range -1 to 99 bar (-14.5 to 1435.5 psi). Output 4-20 mA, supply 9-32 V DC. Piezo-resistive silicon MEMS sensing element, sealed-gauge reference. Process connection 1/4-18 NPT male; electrical connection M12 x 1, 4-pin, IEC 61076-2-101; enclosure IP67. Supplied as OEM original where available, or a verified compatible equivalent.
| Type | DST P310 |
| Code number | 076G1020 |
| Measuring range | -1 to 99 bar (-14.5 to 1435.5 psi) |
| Output signal | 4-20 mA |
| Supply voltage | 9-32 V DC |
| Accuracy | ±0.5% FS typical, ±1% FS maximum (total error band) |
| Sensing | piezo-resirigide silicon MEMS, sealed-gauge reference |
| Process connection | 1/4-18 NPT male |
| Electrical connection | M12 x 1, 4-pin, IEC 61076-2-101 |
| Enclosure | IP67 |
| Media temperature | -40°C to +85°C |
| Ambient temperature | -40°C to +85°C |
| Weight | 0.137 kg |
| Product group | Sensors |
| Approval | C UL US UL Recognized; CE |
| UL mark | Yes |
| CE mark | Yes |
| REACH candidate-list substances | Lead (CAS no. 7439-92-1) |
| EAN | 5702424593810 |
| Accuracy, max. | 1.00 % |
| Accuracy, typical | 0.5 % |
| Adj. zero point and span | No |
| Compensated temp. range | -40 °C to 125 °C |
| Electrical conn | |
| Male/Female | Male |
| Electrical connection size | 4 pin |
| Electrical connection standard | IEC 61076-2-101 |
| Enclosure rating IP | IP67 |
| Flush diaphragm | No |
| High Clipping Level | 22.40 |
| Intrinsically safe | No |
| Low Clipping level | 3.60 |
| Negative / common | Pin 2 |
| Non-linearity BFSL | 0.50 % |
| Overload pressure max. | 600.0 bar |
| Positive / supply | Pin 1 |
| Pressure connection HEX | 27.0 mm |
| Pressure connection size | 1/4-18 |
| Pressure connection standard | ANSI/ASME B1.20.1 |
| Pressure connection type | NPT |
| Pressure Male/Female | Male |
| Material | 316L stainless steel wetted parts (depending on pressure port) |
| Pressure rating | Overload 600 bar; response time <=4 ms |
| Temperature range | -40°C to +85°C |
| IP rating | IP67 |
| MOQ | 1 |
Verify code number, measuring range, output signal (ratiometric / 4-20 mA), process connection and electrical connection before ordering.