cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-08
sales@cballast.com
cballast.com

Danfoss MBS 4251 Intrinsically Safe Pressure Transmitter 0 to 6 bar (060G6304)

Danfoss · Sensors & Instrumentation · Pressure Transmitters · Denmark · danfoss.com
Part Number
060G6304  ·  HS 9026.20
Danfoss MBS 4251 Intrinsically Safe Pressure Transmitter 0 to 6 bar (060G6304)

Danfoss MBS 4251 intrinsically safe pressure transmitter for hazardous areas. Measuring range 0 to 6 bar (0 to 87 psi), 4-20 mA current output, AISI 316L stainless steel wetted parts. Pressure connection G 1/4 (DIN 3852-E, ISO 1179-2, Form E); electrical connection 5 m cable. Ex ia IIC T5.T4 Ga/Gb intrinsically safe; supply 10-28 V DC. Approvals: ATEX, CE, UL Recognized (C UL US). EAN 5702428874656.

Technical Specifications

TypeMBS 4251 (intrinsically safe)
Range0 to 6 bar (0 to 87 psi)
Output4-20 mA (2-wire)
Supply10-28 V DC
Wetted partsAISI 316L stainless steel
Pressure connectionG 1/4 (DIN 3852-E, ISO 1179-2, Form E)
Electrical connectionCable, 5 m
Ex protectionEx ia IIC T5..T4 Ga/Gb
EnclosureIP67
Media temp-20 to 85°C
ApprovalsATEX, CE, UL Recognized (C UL US)
EAN5702428874656
Part number060G6304
Net weight0.448 Kilogram
Product groupSensors
+ supplyBlack 1
- commonBlack 2
Accuracy, max. [±FS%]1 %
Accuracy, typical [±FS%]0.5 %
Adj. zero point and spanNo
ApprovalATEX
Cable length [in]196 in
Cable length [m]5 m
CE markYes
China RoHS complianceOut of scope
CommentsMEDIUM TEMP. MIN -20°C VITON
Compensated temp. range [°C] [max]100 °C
Compensated temp. range [°C] [min]0 °C
Compensated temp. range [°F] [max]212 °F
Compensated temp. range [°F] [min]32 °F
EEE category5 small equipment (any external dimension < 50 cm)
Electrical conn. commentsScreened Ex
Enclosure rating IPIP67
EU RoHS complianceYes with exemptions
EU RoHS exemption clause6(c)
EX Sales textEx iA IIC T5..T4 Ga/Gb
Flush diaphragmNo
High Clipping Level22.4
In scope of WEEEYes
International Article Number5702428874656
Intrinsically safeYes
Low Clipping level3.6
Medium temperature range [°C] [max]85 °C
Medium temperature range [°C] [min]-20 °C
Medium temperature range [°F] [max]185 °F
Medium temperature range [°F] [min]-4 °F
Non-linearity BFSL [±FS%]0.2 %
Output signalCurrent
Output signal [mA] [max]20 mA
Output signal [mA] [min]4 mA
Overload pressure max. [bar]36 bar
Overload pressure max. [psi]522 psi
Pressure connection HEX [mm]27 mm
Pressure connection notesM5
Pressure connection size1/4
Pressure connection standardDIN 3852-E
Pressure connection typeG
Pressure Male/FemaleMale
Pressure range [bar] [max]6 bar
Pressure range [bar] [min]0 bar
Pressure range [psi] [max]87 psi
Pressure range [psi] [min]0 psi
Pressure referenceGauge (relative)
Pulse-snubberYes
REACH Candidate List substancesLead (CAS no. 7439-92-1)
Response time max. [ms]4 ms
Specification keyMBS 4251-1811-DCGB04-1
Supply voltage [V] DC [max]28 V
Supply voltage [V] DC [min]10 V
UL markYes

Properties

MaterialAISI 316L stainless steel wetted parts
Pressure rating0 to 6 bar
Temperature range-40°C to +85°C (medium/ambient)
IP ratingIP67
Thread standardDIN 3852-E / ISO 1179-2
MOQ1

Compatibility

MBS 4251 intrinsically safe (Ex ia IIC) transmitter for hazardous areas; requires certified barrier/isolator.

Standards

Attached Documents