| Housing | Stainless steel 1.4301 (304) |
| Standard version | Stainless steel 1.4471 (316Ti) |
| Standard flush diaphragm version | Stainless steel 1.4471 (316Ti), FKM seal |
| Hygienic flush diaphragm version | Stainless steel 1.4404 (316L), EPDM seal |
| Internal transmitting liquid | Synthetic Oil (for standard version with pressure range < 16 bar (232 PSI) and for all flush |
| Measurement technology | Piezo (≤ 16 bar) / Thin film (25 bar) |
| Compensated T° range | 0…+ 80 °C (+ 32…+ 176 °F) |
| Welding socket for pressure transmitter | Standard flush diaphragm version: G ½" B or G 1" B |
| Temperature coefficient (Tc) | In compensated T° range |
| Flush diaphragm version | ≤ - 0.2…+ 0.3 % of full scale/10K |
| Standard and flush diaphragm version | ≤ ± 0.2 % of full scale/10K |
| Response time | ≤ 1 ms |
| Measurement deviation | ≤ 0.5 % of full scale (2-point calibration)1.) |
| Hysteresis | ≤ 0.1 % of full scale |
| Repeatability | ≤ 0.05 % of full scale |