AF1250-30-11 24-60VDC (1SFL647001R6811)

ABB · Electrical Components · Contactors · Switzerland · abb.com
Part Number
1SFL647001R6811  ·  HS 8536.49
AF1250-30-11 24-60VDC (1SFL647001R6811)

ABB 1SFL647001R6811 — The AF1250-30-11-68 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and Main Circuit Bars, switching power circuits up to 1260 A (AC-1) or 1210 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (24-60 V DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.

Technical Specifications

Manufacturer part number (MPN)1SFL647001R6811
EAN / GTIN7320500346075
Sales unitpcs
Voltage24-60 V DC
Country of OriginIndia
Product Sales StatusActive
Product Net Width210 mm
Product Net Depth / Length242 mm
Product Net Height344 mm
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles3P
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (I th )acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A
Rated Operational Current AC-1 (I e )(1000 V) 40 °C 1260 A; (1000 V) 55 °C 1040 A; (1000 V) 70 °C 875 A; (690 V) 40 °C 1260 A; (690 V) 55 °C 1040 A; (690 V) 70 °C 875 A
Rated Operational Current DC-1 (I e )(220 V) 3 Poles in Series, 40 °C 1250 A; (600 V) 3 Poles in Series, 40 °C 1250 A; (850 V) 3 Poles in Series, 40 °C 1250 A
Rated Operational Current DC-3 (I e )(220 V) 3 Poles in Series, 40 °C 1250 A; (600 V) 3 Poles in Series, 40 °C 1250 A; (850 V) 3 Poles in Series, 40 °C 1250 A
Rated Operational Current DC-5 (I e )(220 V) 3 Poles in Series, 40 °C 1250 A; (600 V) 3 Poles in Series, 40 °C 1250 A; (850 V) 3 Poles in Series, 40 °C 1250 A
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (I cw )at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1500 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 5200 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 8000 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7200 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4000 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A; cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
Rated Insulation Voltage (U i )acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V; acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 1000 V; acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (U imp )Main Circuit 8 kV
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour
Mechanical Durability0.5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (U c )DC Operation 24 ... 60 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A; Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A; Holding at Max. Rated Control Circuit Voltage DC 4.5 V·A; Holding at Max. Rated Control Circuit Voltage DC 4.5 W; Pull-in at Max. Rated Control Circuit Voltage 50 Hz 780 V·A; Pull-in at Max. Rated Control Circuit Voltage 60 Hz 780 V·A; Pull-in at Max. Rated Control Circuit Voltage DC 1135 V·A; Pull-in at Max. Rated Control Circuit Voltage DC 1135 W
Power Lossat Rated Operating Conditions per Pole 80 W
Operate TimeBetween Coil De-energization and NC Contact Closing 50 ... 70 ms; Between Coil De-energization and NO Contact Opening 53 ... 73 ms; Between Coil Energization and NC Contact Opening 45 ... 115 ms; Between Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main CircuitBar 50 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm²; Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²; Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²; Flexible 1x0.75 ... 2.5 mm²; Flexible 2x0.75 ... 2.5 mm²; Solid 2 x 1 ... 4 mm²; Stranded 2 x 1 .... 4 mm²
Connecting CapacityBar 50 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20; acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main PolesM 3.5 (+,-) pozidriv 2 screw with cable clamp
Recommended Screw DriverMain Circuit M12; Control Circuit Pozidriv 2; Control Circuit M3.5
Tightening TorqueCable Lug 45 N·m; Main Circuit 45 N·m
Terminal TypeMain Circuit: Bars
Suitable for Product ClassBlock ContactorsBlock Contactors
Horsepower Rating NEMA(230 V AC) Three Phase 300 Hp; (460 V AC) Three Phase 600 Hp; (575 V AC) Three Phase 600 Hp
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(1000 V AC) 1210 A
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C; Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C; Close to Contactor for Storage -40 ... 70 °C; Operation -40 ... 70 °C; Storage -40 ... +70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Shock Direction: A 5 g; Shock Direction: B1 5 g; Shock Direction: B2 5 g; Shock Direction: C1 5 g; Shock Direction: C2 5 g
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
EcoSolutions Profile1SFC100125C0366
End Of Life Disassembling Instructions1SFC100112M0004
Environmental Product Declaration - EPD1SFC100109D0201; 2TFP200025A1001
Extended Product LifetimeProduct Durability
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 69.7 %
ABS Certificate15-LD1408622-PDA
BV CertificateBV_13409-C0BV
CB CertificateSE-82863
CCS CertificateGB14T00030; GZ15T00069
CQC CertificateCQC2006010304213519; CQC2012010304540079
cULus CertificateUL_20130930-E73397
Declaration of Conformity - CE2CMT2019-005796
Declaration of Conformity - UKCA2CMT2020-006118
DNV CertificateTAE00001W1
LR Certificate16-20064
PRS CertificateTE_2092_880423_16
RINA CertificateELE060313XG_002
UL Listing CardUL_E73397
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
E-Number (Norway)4115380
E-Number (Sweden)4115380

Properties

MOQ1

Cross-References

Attached Documents