ABB 2CTB803876R1000 OVR T2 40-275 C QS Surge Protective Device

ABB · Switchgear & Protection · Surge Protectors · Switzerland · abb.com
Part Number
2CTB803876R1000  ·  HS 8535.40
ABB 2CTB803876R1000 OVR T2 40-275 C QS Surge Protective Device

ABB 2CTB803876R1000 — OVR T2 40-275 C QS Surge Protective Device.

Technical Specifications

Manufacturer part number (MPN)2CTB803876R1000
EAN / GTIN3660308520890
Sales unitpcs
Carbon Footprint (Full Lifecycle)8.897472 kg CO₂ eq
EcoSolutions Profile9AKK108472A3406
Type of Low Voltage Distribution SystemTT; TN-C; TN-S
Suitable ForTo protect the systems against the transient overvoltages (lightning)
Nominal AC Voltage of the System (U o )230 / 400 V
Maximum Continuous Operating Voltage (U c )(L-PE) 275 V
Temporary Overvoltage Test Value (U T )337 V
Rated Service Short-Circuit Breaking Capacity (I cs )100 kA
Discharge CurrentNominal (8 / 20 µs) 20 kA; I (max, 8 / 20 µs) 40 kA
Impulse CurrentI (imp, 10 / 350 µs, L-N) 2 kA
Short Circuit Withstand Icc100 kA
Arrester ClassII
Number of Protected Poles1
Number of Poles1P
Number of Conductors1
Transmission StandardOptic
VersionPlug-in
Product TypeQS
Options ProvidedReplacement Cartridge
Preventive Maintenance FeatureNo
Status IndicatorYes
Fuse Size4 modular spacing
Cross-Section ( A cross )Maximum Conductor Solid-Stranded 25 mm²; Maximum Conductor Flexible 16 mm²
Rated Voltage (U r )230 V AC
Voltage Protection Level ( Up)1.25 kV; (L-N) 1.25 kV; (N-PE) 1.25 kV
Degree of ProtectionIP20
Maximum Operating Altitude PermissibleWithout Derating 5000
Width in Number of Modular Spacings1
Product Net Width17.6 mm
Product Net Height57 mm
Product Net Depth / Length55.6 mm
CB Certificate2CTC432024G1701
CQC Certificate9AKK107680A1974
Declaration of Conformity - CE9AKK108466A4410
Instructions and Manuals2CTC432097M1701
Mounting TypeDIN-Rail
ETIM 9EC000941 - Surge protection device for power supply systems
UNSPSC39121610
eClassV11.0 : 27130805
Object Classification Code141DCC
StandardsIEC 61643-11 / EN 61643-11
System configurationTN-S
System configuration DCNo
System configuration ITNo
System configuration TNYes
System configuration TN-CNo
System configuration TTNo
System configuration otherNo
Nominal discharge surge current (8/20)20 kA
Max. discharge surge current (8/20)20 kA
Short-circuit-proofYes
Nominal voltage AC230 V
Max. continuous voltage AC275 V
Max. continuous voltage DC350 V
Voltage protection level L-N1.25 kV
Voltage protection level N-PE1.25 kV
Max. overcurrent protection device, series connection (fuse)125 A
Short-circuit breaking capacity (Isccr)100 kA
Integrated short-circuit protectionNo
Integrated backup fuseNo
Leakage-current freeNo
Construction size4 modular spacing
Max. conductor cross section solid (solid, stranded)25 mm²
Max. conductor cross section flexible (fine-strand)16 mm²
With remote signalling contactNo
Signalling at the deviceOptical
Category type 2Yes
Country of originBulgaria

Properties

MOQ1

Cross-References