cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

WIKA 732.51 differential pressure gauge 0-1 bar NS100 2X G1/2

WIKA · Gauges & Measurement · Pressure Gauges · Germany · wika.com
Part Number
732.51.100-1BAR  ·  HS 9026.20
WIKA 732.51 differential pressure gauge 0-1 bar NS100 2X G1/2

WIKA model 732.51 differential-pressure gauge, NS 100, 0 to 1 bar differential, 2 x G1/2 female. All-stainless-steel case with all-metal media chamber and 316Ti diaphragm element for aggressive liquid and gaseous media, no elastomer process seals. Accuracy class 1.6 (1.0 / 2.5 selectable) per EN 837-1, safety level S1 (blow-out device). High overload safety up to 40 bar static, either side.

Technical Specifications

Model732.51
Nominal sizeNS 100 (100 mm dial)
Differential range0 to 1 bar
Accuracyclass 1.6 (1.0 / 2.5 selectable)
Casestainless steel 1.4301 (304); 1.4571 (316Ti) optional
Media chamber / diaphragm element (wetted)stainless steel 1.4571 (316Ti)
Constructionall-metal media chamber, no elastomer process seals
Process connection2 x G1/2 female (EN 837-1/7.3); 2x G1/2 B male / 2x 1/4 NPT optional
Safetyblow-out device (EN 837-1 safety level S1)
Overload / max. static pressureup to 40 bar either side
Ingress protectionIP54 (IP65 with case filling)
Low-temperature optionPOLARgauge to -70 °C
StandardEN 837-1

Properties

MaterialStainless steel case (1.4301 / 304); all-metal media chamber and diaphragm element stainless steel 1.4571 (316Ti) wetted; no elastomer process seals
Pressure rating0 to 1 bar differential; overload / max. static (either side) up to 40 bar
Temperature range-20 to +60 °C ambient
IP ratingIP54
Primary standardEN 837-1
Standard size100 mm
Thread standard2 x G1/2 female (EN 837-1/7.3)
DimensionsNS 100 mm dial
MOQ1

Compatibility

WIKA 732.51 differential-pressure gauges suit filter, pump and level monitoring on liquid and gaseous aggressive media. Interchange with equivalent all-metal DP gauges at the same nominal size, differential range, process connection and overload rating. Confirm differential range, static-pressure rating and connection before ordering.

Standards

Approvals