Wedeco VLR 2 for Spektron 2E Replacement UV Lamp

Wedeco · Electrochlorination & Water Treatment · UV Lamps · Germany · xylem.com
Part Number
13336-1119  ·  HS 8539.49
Wedeco VLR 2 for Spektron 2E Replacement UV Lamp

A UV lamp is a scheduled replacement, not a failure item. Its UV-C output falls steadily through life while the lamp continues to light normally, so a reactor with visibly working lamps can be well below its dosing duty. Replace on elapsed operating hours against the measured intensity trend, not on the lamp going out, and handle the new lamp by its ends only. The matching quartz sleeve for this reactor is stocked under item 13379-0321. Wedeco was founded in Herford, Germany in 1976 and is now a Xylem brand.

Technical Specifications

Component typeUV lamp
FitsWedeco VLR 2, Spektron 2E
HS code8539.49

Properties

MaterialQuartz glass envelope, amalgam
Temperature rangeOperating: 40°C bulb wall typical
MOQ1

Compatibility

Fits Wedeco Spektron / Spektron e UV drinking-water disinfection reactors (Xylem).

Cross-References