A UV lamp is a scheduled replacement, not a failure item. Its UV-C output falls steadily through life while the lamp continues to light normally, so a reactor with visibly working lamps can be well below its dosing duty. Replace on elapsed operating hours against the measured intensity trend, not on the lamp going out, and handle the new lamp by its ends only. This is the lamp for the SLF2860. The matching quartz sleeve for the SLR 2860 position is stocked under item 13235-1115. Wedeco was founded in Herford, Germany in 1976 and is now a Xylem brand.
| Component type | UV lamp |
| Fits | Wedeco SLF2860 |
| Compatible with SLF2860 | |
| HS code | 8539.49 |
| Material | Quartz glass envelope, amalgam |
| Temperature range | Operating: 40°C bulb wall typical |
| MOQ | 1 |
Genuine replacement for Wedeco (Xylem) UV / ozone systems.