Ultraviolet control cabinets dissipate real heat from ballasts and ignitors into a largely sealed enclosure. A blinded filter is the usual first cause of a cabinet running hot: airflow falls gradually, so temperature-related faults appear long before anyone suspects the filter. Replace on a routine interval rather than on symptoms. This is the cabinet fan for the Spektron 6. Wedeco was founded in Herford, Germany in 1976 and is now a Xylem brand.
| Component type | Cabinet cooling fan |
| Fits | Wedeco Spektron 6 |
| HS code | 8421.99 |
| MOQ | 1 |
Fits Wedeco Spektron / Spektron e UV drinking-water disinfection reactors (Xylem).