VEGA non-contact 80 GHz radar level sensor with display/adjustment module

VEGA · Sensors & Instrumentation · Level Sensors · Germany · vega.com
Part Number
VEGAPULS 31  ·  HS 9026.10
Image not available for this product

VEGA VEGAPULS 31 non-contact radar level sensor for continuous level measurement of liquids and bulk solids in standard applications, with a plug-in display and adjustment module for on-site reading and setup. 80 GHz radar with an 8° beam angle, measuring range to 20 m and accuracy ± 2 mm. Plastic housing with PVDF process fitting and FKM seal; threaded process connection (G1½, 1½ NPT or R1½). Output 4. 20 mA/HART; setup by the display/adjustment module, by PC/PACTware/DTM or by smartphone, tablet or PC over Bluetooth. Degree of protection IP66/IP67 (Type 4X). Supplied as a VEGA configured item; confirm the order code for the required range, output, process fitting and electronics.

Technical Specifications

TypeVEGA VEGAPULS 31
Measuring principlenon-contact radar, 80 GHz (W-band)
Medialiquids and bulk solids
Measuring rangeup to 20 m (66 ft)
Accuracy (deviation)± 2 mm
Beam angle8°
Process temperature-40 ... +80 °C (-40 ... +176 °F)
Process pressure-1 ... +3 bar (-100 ... +300 kPa)
Ambient temperature-40 ... +80 °C
Process fittingthread G1½, 1½ NPT, R1½
Wetted parts materialPVDF
Seal materialFKM
Housing materialplastic
Signal output4 ... 20 mA/HART
Displayplug-in display and adjustment module
Adjustmentdisplay/adjustment module; PC, PACTware and DTM; smartphone / tablet / PC via Bluetooth
Degree of protectionIP66 / IP67, Type 4X
ApprovalsCE (optional Ex / regional / ship approvals available per configuration)

Properties

MaterialPVDF wetted parts; FKM seal; plastic housing
Pressure rating-1 ... +3 bar
Temperature range-40 °C to +80 °C
IP ratingIP66/IP67 (Type 4X)
MOQ1

Compatibility

Non-contact 80 GHz radar with on-site display/adjustment module, 4 … 20 mA/HART output and Bluetooth setup; range to 20 m. Standard threaded instrument (IP66/IP67 Type 4X); select process fitting (G/NPT/R) to suit the application.

Approvals