Trojan UV intensity sensor for 8000S series UV disinfection systems built in the single-ballast configuration. It measures UV intensity inside the reactor so the controller can verify the delivered dose and raise a low-UV alarm when lamp output or water transmittance falls below the set point. Confirm the ballast configuration of the installed system before ordering, as the sensor differs between single- and multi-ballast builds.
| Type | UV intensity sensor |
| Compatible system | Trojan 8000S |
| Configuration | Single ballast |
| Function | UV dose monitoring and low-UV alarm |
| HS code | 8543.70 |
| MOQ | 1 |
Compatible with Trojan System 8000 S/L wastewater UV disinfection system.