Schneider Electric Complete body/contact assembly, Harmony XB5, XB4, single contact block with body/fixing collar 2NC plug in connector ZB5AZ1044

Telemecanique · Control & Automation · Pushbuttons & Pilot Lights
Part Number
ZB5AZ1044  ·  HS 8536.50
Schneider Electric Complete body/contact assembly, Harmony XB5, XB4, single contact block with body/fixing collar 2NC plug in connector ZB5AZ1044

Telemecanique ZB5AZ1044 Contact Body in plastic consisting of 2xNC connector with plug connection.

Technical Specifications

Manufacturer part number (MPN)ZB5AZ1044
EAN / GTIN3389110925739
Sales unitpcs
Range of productHarmony XB5
Product or component typeComplete body/contact assembly
Device short nameZB5
Fixing collar materialPlastic
Sale per indivisible quantity1
Head typeStandard
Contacts type and composition2 NC
Contact operationSlow-break
Contact block typeSingle
Connections - terminalsPlug-in connector
CAD overall width30 mm
CAD overall height42 mm
CAD overall depth32 mm
Terminals description ISO n°1(11-12)NC
Product weight0.026 kg
Device compositionFixing collar; Body
Contacts usageStandard contacts
Positive openingWith conforming to IEC 60947-5-1 appendix K
Operating travel1.5 mm (NC changing electrical state); 4.3 mm (total travel)
Mechanical durability10000000 cycles
Contacts materialSilver alloy (Ag/Ni)
Short-circuit protection4 A cartridge fuse type gG conforming to IEC 60947-5-1
[Ith] conventional free air thermal current10 A conforming to IEC 60947-5-1
[Ui] rated insulation voltage250 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage4 kV conforming to IEC 60947-1
[Ie] rated operational current3 A at 240 V, AC-15, A300 conforming to IEC 60947-5-1; 6 A at 120 V, AC-15, A300 conforming to IEC 60947-5-1; 0.1 A at 250 V, DC-13, R300 conforming to IEC 60947-5-1; 0.22 A at 125 V, DC-13, R300 conforming to IEC 60947-5-1
Electrical durability1000000 cycles, AC-15, 1 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, AC-15, 1.5 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, AC-15, 3 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.15 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C; 1000000 cycles, DC-13, 0.4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Electrical reliabilityΛ < 10exp(-6) at 5 V, 1 mA in clean environment conforming to IEC 60947-5-4; Λ < 10exp(-8) at 17 V, 5 mA in clean environment conforming to IEC 60947-5-4
Protective treatmentTH
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-40…70 °C
IP degree of protectionIP20 conforming to IEC 60529
StandardsIEC 60947-1; IEC 60947-5-1; CSA C22.2 No 14; JIS C8201-5-1; UL 508; IEC 60947-5-4; JIS C8201-1
Product certificationsBV; UL; CSA; DNV; LROS (Lloyds register of shipping)
Vibration resistance5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
Shock resistance30 gn (duration = 18 ms) for half its wave acceleration conforming to IEC 60068-2-27; 50 gn (duration = 11 ms) for half its wave acceleration conforming to IEC 60068-2-27
Number of Units in Package 11
Number of Units in Package 2160
Number of Units in Package 32560
Country of originFR
Warranty (in months)18