Contact element (XESB2011)

Telemecanique · Control & Automation · Pushbuttons & Pilot Lights
Part Number
XESB2011  ·  HS 8536.50
Contact element (XESB2011)

Telemecanique XESB2011 Oversikt over inch enclosureer, buttons and contact elements.

Technical Specifications

Manufacturer part number (MPN)XESB2011
EAN / GTIN3389110607987
Sales unitpcs
Package quantity100 pcs
Range of productHarmony XAC
Product or component typeContact block
Component nameXESB
Electrical circuit typeControl circuit
Contact block applicationSingle speed
Contact block typeSingle
Type of operatorSpring return
Product compatibilityXACM; XACB; XAB91...
Mechanical interlockingWithout mechanical interlock
Mounting of blockFront mounting
Contact operationSnap action
Connections - terminalsScrew clamp terminals, 1 x 2.5 mm² with or without cable end; Screw clamp terminals, 2 x 1.5 mm² with or without cable end
Mechanical durability1000000 cycles
Contact code designationA300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A; Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current10 A
[Ui] rated insulation voltage500 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947-1
Maximum resistance across terminals25 MOhm
Operating force25 N; 15 N
Short-circuit protection10 A fuse protection by cartridge fuse type gG
Rated operational power in W140 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 140 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 95 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Rated operational power in VA100 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load); 450 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load); 50 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load); 750 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load)
Terminals description ISO n°1(3-4-1-2)OF
Terminal identifier(13-14)NO; (11-12)NC
StandardsIEC 60947-5-1; CSA C22.2 No 14; IEC 60947-5-1
Ambient air temperature for operation-25…70 °C
Ambient air temperature for storage-40…70 °C
Vibration resistance15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Shock resistance100 gn conforming to IEC 60068-2-27
Electrical shock protection classClass II conforming to IEC 61140
Number of Units in Package 11
Number of Units in Package 2100
Country of originCZ
Warranty (in months)18

Properties

MOQ1

Cross-References

Attached Documents