| Manufacturer part number (MPN) | XENC1151 |
| EAN / GTIN | 3389110643084 |
| Sales unit | pcs |
| Package quantity | 100 pcs |
| Range of product | Harmony XAC |
| Product or component type | Contact block |
| Component name | XENC |
| Electrical circuit type | Control circuit |
| Contact block application | Single speed |
| Contact block type | Single |
| Type of operator | Spring return |
| Product compatibility | XACB; XACM |
| Mechanical interlocking | Without mechanical interlock |
| Contacts type and composition | 1 NC + 1 NO |
| Mounting of block | Front mounting |
| Contact operation | Slow-break |
| Connections - terminals | Screw clamp terminals, 1 x 2.5 mm² with or without cable end; Screw clamp terminals, 2 x 1.5 mm² with or without cable end |
| Mechanical durability | 1000000 cycles |
| Contact code designation | A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A; Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A |
| [Ithe] conventional enclosed thermal current | 10 A |
| [Ui] rated insulation voltage | 500 V (pollution degree 3) conforming to IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
| Maximum resistance across terminals | 25 MOhm |
| Short-circuit protection | 10 A fuse protection by cartridge fuse type gG |
| Rated operational power in W | 42 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 45 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C; 60 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C |
| Rated operational power in VA | 140 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load); 385 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load); 455 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load); 525 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load) |
| Terminals description ISO n°1 | (11-12)NC; (23-24)NO |
| Terminal identifier | (11-12)NC; (13-14)NO |
| Product weight | 0.02 kg |
| Standards | IEC 60947-5-1; CSA C22.2 No 14; IEC 60947-5-1 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…70 °C |
| Vibration resistance | 15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 100 gn conforming to IEC 60068-2-27 |
| Number of Units in Package 1 | 1 |
| Number of Units in Package 2 | 100 |
| Country of origin | CZ |
| Warranty (in months) | 18 |