Telemecanique XUK9LAPSMM12 Laser Photoelectric Sensor, Polarised Reflex, Sn 12 m, M12 Connector

Telemecanique · Sensors & Instrumentation · Photoelectric Sensors
Part Number
XUK9LAPSMM12  ·  HS 8541.49
Telemecanique XUK9LAPSMM12 Laser Photoelectric Sensor, Polarised Reflex, Sn 12 m, M12 Connector

Telemecanique XUK9LAPSMM12 laser photoelectric sensor, polarised reflex, sensing distance 12 m, NO+NC outputs, M12 connector.

Technical Specifications

Manufacturer part number (MPN)XUK9LAPSMM12
EAN / GTIN3666916037379
Sales unitpcs
Package quantity28 pcs
Nominal sensing distance Sn12 m
Pre failure noticeNo
With time functionNo
Rated switching distance12000 mm
Max. switching distance14000 mm
Max. output current100 mA
With reflectorYes
Analogue output 0 V ... 10 VNo
Analogue output 0 mA ... 20 mANo
Analogue output 4 mA ... 20 mANo
Analogue output -10 V ... +10 VNo
With other analogue outputNo
Setting procedureParameterization
With communication interface analogueNo
With communication interface AS-InterfaceNo
With communication interface CANOpenNo
With communication interface DeviceNetNo
With communication interface EthernetNo
With communication interface INTERBUSNo
With communication interface PROFIBUSNo
With communication interface RS-232No
With communication interface RS-422No
With communication interface RS-485No
With communication interface SSDNo
With communication interface SSINo
Number of semiconductor outputs with signalling function1
Number of protected semiconductor outputs1
Type of electric connectionConnector M12
Type of switching outputPNP/PNP
Type of switch functionProgrammable/configurable
Operation agent-safety classSafety class 0
Explosion safety category for gasNone
Explosion safety category for dustNone
Construction type housingCuboid
Width sensor18 mm
Height of sensor50 mm
Length of sensor50 mm
Sensing modeDark switching
Material of optical surfacePlastic
Housing materialPlastic
Max. output current at protected output100 mA
Min. reflector distance5000 mm
Ambient temperature-20–60 °C
Response time25 ms
Switching frequency2000 Hz
Type of safety according to IEC 61496-11
Rated control supply voltage DC10–30 V
Voltage typeAC/DC
With monitoring function downstream switching devicesNo
Laser protection classClass 1
Type of lightLaser diode, red light
With restart blockageNo
Suitable for safety functionsNo
Degree of protection (IP)IP67K
Country of originGermany

Properties

MOQ1

Cross-References

Attached Documents