Generic STP-TMP-D STP MBR Transmembrane Pressure Sensor -1 to +1 bar 4-20 mA 316L Differential (replacement) — service spare for marine sewage-treatment plant membrane-bior.
| Material | 316L stainless flush-diaphragm + ceramic capacitive sensor |
| Standards | IMO MARPOL Annex IV Regulation 9, IMO MEPC.227(64) revised guidelines on implementation of effluent standards and performance tests for STP, IEC 61298-1 process measurement and control devices — general methods, IEC 60770-1 transmitters for use in industrial-process control systems |
| Approvals | CE EMC 2014/30/EU, CE PED 2014/68/EU Article 4(3) SEP, NIST-traceable factory calibration certificate at two points, MEPC.227(64) effluent-compliance compatible when fitted as like-for-like on type-approved STP |
| HS code | 8421.99 |
| Pressure | 1 bar |
| Material | 316L stainless flush-diaphragm + ceramic capacitive sensor |
| MOQ | 1 |
Form-fit envelope for Hamworthy ST series, EVAC MBR, Wartsila Aquarius MBR, Hyundai-Wilson HMS-MBR, Detegasa Pro, RWO MBR, Headhunter T marine sewage-treatment plant transmembrane-pressure sensor change-out, dissolved-oxygen probe renewal (optical, galvanic, membrane-cap consumables) and sludge-density meter replacement (ultrasonic, optical backscatter, tuning-fork) + analyser transmitter + calibration consumables.