O-Ring 38 x 5 mm for SITA Quartz Sleeve 400 Series, 028207, article 3835-0314. Data: inside diameter 38 mm, cross-section 5 mm. OEM reference: 028207 / SI028207. Fits: SITA 400 series. Sleeve and chamber seals harden under UV, heat and chlorinated water. Replace them at every lamp or sleeve service; a re-used O-ring is the usual cause of a leaking sleeve gland. SITA HDPE series data: high-density polyethylene chamber for seawater and corrosive liquids, 1-980 m3/h, low-pressure high-efficiency or amalgam lamps with 9,000-16,000 h lamp life, 6 bar. Spare part for UV disinfection systems of S.I.T.A. srl, Genoa, Italy, which builds low-pressure, amalgam and medium-pressure UV units for drinking water, food and beverage, aquaculture, swimming pool, marine and wastewater duty (series AL, LCD / Rack LCD, AM, IT, 440, HDPE, SBT, SMP, SSD, TOC, GR and Pool).
| Part number | 028207 |
| Article number | 3835-0314 |
| OEM reference | 028207 / SI028207 |
| System manufacturer | S.I.T.A. srl (SITA UV), Italy |
| Component type | O-ring / seal |
| Inside diameter | 38 mm |
| Cross-section | 5 mm |
| Fits | SITA 400 series |
| HS code | 4016.93 |
| MOQ | 1 |
Fits: SITA 400 series