| Manufacturer part number (MPN) | 6ES7138-6CG00-0BA0 EAN / GTIN: 4047623404712 Sales unit: pcs Product type designation: TM Timer DIDQ 10x24V Engineering with — STEP 7 TIA Portal configurable/integrated from version: V13 Update 3 Engineering with — STEP 7 configurable/integrated from version: V5.5 SP3 / - Rated value (DC): 24 V Load voltage L+ — Rated value (DC): 24 V Load voltage L+ — permissible range, lower limit (DC): 19.2 V Load voltage L+ — permissible range, upper limit (DC): 28.8 V Current consumption, max.: 50 mA; without load Number of outputs: 1 24 V encoder supply — 24 V: Yes; L+ (-0.8 V) 24 V encoder supply — Output current, max.: 500 mA; Observe derating Power loss, typ.: 1.5 W Address space per module — Inputs: 26 byte Address space per module — Outputs: 32 byte Number of digital inputs: 4 digital input functions, parameterizable — Number, max.: 4 Input voltage — Rated value (DC): 24 V Input voltage — for signal "0": -5 ... +5 V Input voltage — for signal "1": +11 to +30V Input voltage — permissible voltage at input, min.: -30 V; -5 V continuous, -30 V brief reverse polarity protection Input voltage — permissible voltage at input, max.: 30 V Input current — for signal "1", typ.: 2.5 mA Input delay (for rated value of input voltage) — minimum pulse width for program reactions: 3 µs; for parameterization "none" For standard inputs — parameterizable: Yes; none / 0.05 / 0.1 / 0.4 / 0.8 ms Cable length — shielded, max.: 1 000 m; Depending on sensor, cable quality and rate of change Cable length — unshielded, max.: 600 m; Depending on sensor, cable quality and rate of change Number of digital outputs: 6 Short-circuit protection — Response threshold, typ.: 1.7 A with Standard output, 0.5 A with High Speed output Limitation of inductive shutdown voltage to: -0.8 V digital output functions, parameterizable — Number, max.: 6 Switching capacity of the outputs — with resistive load, max.: 0.5 A; 0.1 A with High Speed output Switching capacity of the outputs — on lamp load, max.: 5 W; 1 W with High Speed output Output voltage — for signal "0", max.: 1 V; With High Speed output Output voltage — for signal "1", min.: 23.2 V; L+ (-0.8 V) Output current — for signal "1" rated value: 0.5 A; 0.1 A with High Speed output, observe derating Output current — for signal "1" permissible range, max.: 0.6 A; 0.12 A with High Speed output, observe derating Output current — for signal "1" minimum load current: 2 mA Output current — for signal "0" residual current, max.: 0.5 mA Output delay with resistive load — "0" to "1", max.: 1 µs; With High Speed output, 5 µs with Standard output Output delay with resistive load — "1" to "0", max.: 1 µs; With High Speed output, 6 µs with Standard output Switching frequency — with resistive load, max.: 10 kHz Switching frequency — on lamp load, max.: 10 Hz Total current of the outputs — Current per module, max.: 3.5 A; Observe derating Connectable encoders — permissible quiescent current (2-wire sensor), max.: 1.5 mA Encoder signals, incremental encoder (asymmetrical) — Input voltage: 24 V Encoder signals, incremental encoder (asymmetrical) — Input frequency, max.: 50 kHz Encoder signals, incremental encoder (asymmetrical) — Counting frequency, max.: 200 kHz; with quadruple evaluation Encoder signals, incremental encoder (asymmetrical) — Cable length, shielded, max.: 600 m; Depending on input frequency, encoder and cable quality; max. 200 m at 50 kHz Counter — Counting frequency, max.: 200 kHz; with quadruple evaluation Isolation tested with: 707 V DC (type test) Ambient temperature during operation — horizontal installation, min.: -30 °C Ambient temperature during operation — horizontal installation, max.: 60 °C; Observe derating Ambient temperature during operation — vertical installation, min.: -30 °C Ambient temperature during operation — vertical installation, max.: 50 °C; Observe derating Altitude during operation relating to sea level — Installation altitude above sea level, max.: 5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200SP system manual Absolute humidity — dew point, min.: -60 °C; suitable for dry room applications Dimensions — Width: 15 mm Dimensions — Height: 73 mm Dimensions — Depth: 58 mm Weight, approx.: 45 g Supporting protocol for EtherCAT: No Supply voltage DC: 19.2–28.8 V Voltage type (supply voltage): DC Suitable for counting: Yes Suitable for electronic positioning: No Suitable for SSI: No Suitable for single-axis controller: No Suitable for multi-axis positioning: No Suitable for single-axis positioning: No Degree of protection (IP): IP20 Fieldbus connection over separate bus coupler possible: Yes Frequency measurement: No Suitable for rail mounting: Yes Wall mounting/direct mounting: No Front built-in possible: No Rack-assembly possible: No Explosion safety category for gas: None Explosion safety category for dust: None Width: 15 mm Height: 73 mm Depth: 58 mm Country of origin: Germany |