| Manufacturer part number (MPN) | 6ES7517-3FP00-0AB0 EAN / GTIN: 4047623403944 Sales unit: pcs Product type designation: CPU 1517F-3 PN/DP Firmware version: V3.1 STEP 7 TIA Portal configurable/integrated from version: V19 (FW V3.1); V13 Update 3 (FW V1.6) or higher Screen diagonal [cm]: 6.1 cm Supply voltage – Rated value (DC): 24 V permissible range, lower limit (DC): 19.2 V permissible range, upper limit (DC): 28.8 V Mains/voltage failure stored energy time: 5 ms Current consumption (rated value): 1.55 A Current consumption, max.: 1.9 A Inrush current, max.: 1.9 A; Rated value I²t: 0.4 A²·s Infeed power to the backplane bus: 12 W Power consumption from the backplane bus (balanced): 30 W Power loss, typ.: 24 W Work memory – integrated (for program): 3 Mbyte Work memory – integrated (for data): 8 Mbyte Plug-in (SIMATIC Memory Card), max.: 32 Gbyte CPU-blocks – Number of elements (total): 12 000; Blocks (OB, FB, FC, DB) and UDTs Size, max.: 8 Mbyte; For DBs with absolute addressing, the max. size is 64 KB Number of free cycle OBs: 100 Number of cyclic interrupt OBs: 20; with minimum OB 3x cycle of 100 µs Number of startup OBs: 100 S7 counter – Number: 2 048 Retentive data area (incl. timers, counters, flags), max.: 768 kbyte; available retentive memory 700 KB Extended retentive data area (incl. timers, counters, flags), max.: 8 Mbyte Flag – Size, max.: 16 kbyte per priority class, max.: 64 kbyte; max. 16 KB per block Address area – Number of IO modules: 16 384 I/O address area – Inputs: 32 kbyte; All inputs are in the process image I/O address area – Outputs: 32 kbyte; All outputs are in the process image for bit operations, typ.: 2 ns for word operations, typ.: 3 ns for floating point arithmetic, typ.: 12 ns Backup time: 6 wk; At 40 °C ambient temperature, typically Number of PROFINET interfaces: 2 Number of PROFIBUS interfaces: 1 Transmission rate, max.: 12 Mbit/s Number of connectable IO Devices, max.: 512 SIL acc. to IEC 61508: SIL 3 Performance level according to ISO 13849-1: PLe Ambient temperature during storage/transportation – min.: -40 °C Ambient temperature during storage/transportation – max.: 70 °C Installation altitude above sea level, max.: 5 000 m Dimensions – Width: 175 mm Dimensions – Height: 147 mm Dimensions – Depth: 129 mm Weight, approx.: 1 929 g Width: 175 mm Model: Modular Height: 147 mm Depth: 129 mm With display: Yes Suitable for safety functions: Yes Voltage type (supply voltage): DC Memory size: 11 kByte Processing time (1K, binary operation): 2 ms Supporting protocol for LON: No Number of HW-interfaces industrial Ethernet: 2 Number of HW-interfaces RS-485: 1 With optical interface: No Additional program memory possible: No Supporting protocol for TCP/IP: Yes Supporting protocol for ASI: No Supporting protocol for PROFIBUS: Yes Supporting protocol for CAN: No Supporting protocol for INTERBUS: No Supporting protocol for KNX: No Supporting protocol for Modbus: Yes Supporting protocol for Data-Highway: No Supporting protocol for DeviceNet: No Supporting protocol for SUCONET: No Supporting protocol for other bus systems: No Redundancy: No Suitable for rail mounting: Yes Explosion safety category for gas: ATEX gas-ex-protection, Cat. 3G Explosion safety category for dust: None System accessory: Yes Appendant operation agent (Ex ia): No Supporting protocol for SERCOS: No Supporting protocol for INTERBUS-Safety: No Number of interfaces PROFINET: 2 Front built-in possible: No Rack-assembly possible: No Wall mounting/direct mounting: No Radio standard Bluetooth: No Radio standard WLAN 802.11: No IO link master: No Performance level according to EN ISO 13849-1: Level e Supporting protocol for AS-Interface Safety at Work: No Supporting protocol for DeviceNet Safety: No Supporting protocol for EtherNet/IP: No Supporting protocol for Foundation Fieldbus: No Supporting protocol for PROFINET CBA: No Supporting protocol for PROFINET IO: Yes Supporting protocol for PROFIsafe: Yes Supporting protocol for SafetyBUS p: No Supply voltage DC: 19.2–28.8 V Radio standard GPRS: No Radio standard GSM: No Mobile communications standard 3G (UMTS): No SIL according to IEC 61508: 3 Mobile communications standard 4G (LTE): No Supporting protocol for EtherCAT: No Country of origin: Germany |