cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Siemens SIMATIC S7 automation module 6ES7212-1AG50-0XB0

Siemens · Control & Automation · PLCs · Germany · siemens.com
Part Number
6ES7212-1AG50-0XB0  ·  HS 8537.10
Image not available for this product

Siemens 6ES7212-1AG50-0XB0 — SIMATIC S7 automation module. Compact controller or expansion module for the S7-1200 or S7-1500 PLC platform. SIMATIC S7-1200 G2: compact CPU 1212C DC/DC/DC; power supply: DC 20.4-28.8 V DC; onboard In/O: 8x DI.

Technical Specifications

Manufacturer part number (MPN)6ES7212-1AG50-0XB0
EAN / GTIN4047623412823
Sales unitpcs
Product type designationCPU 1212C DC/DC/DC
Firmware versionV4.1
Rated value (DC)24 V DC
Permissible range, lower limit (DC)20.4 V
Permissible range, upper limit (DC)28.8 V
Current consumption (rated value)125 mA; CPU only
Current consumption, max.700 mA; CPU with all expansion modules
Inrush current, max.12 A; at 28.8 V DC
For backplane bus (5 V DC), max.1 000 mA; Max. 5 V DC for SM and CM
24 V encoder supplyL+ minus 4 V DC min.
Encoder supply — Output current, max.300 mA
Power loss, typ.3 W
Work memory — integrated650 kbyte
Work memory — integrated (for program)150 kbyte
Work memory — integrated (for data)500 kbyte
Load memory — integrated8 Mbyte
Load memory — Plug-in (SIMATIC Memory Card), max.32 Gbyte
Number of elements (total)4 000; Blocks (OB, FB, FC, DB) and UDTs
Retentive data area (incl. timers, counters, flags), max.20 kbyte
Flag — Size, max.8 kbyte
I/O address area — Inputs1 kbyte
I/O address area — Outputs1 kbyte
Number of modules per system, max.6
Hardware configuration — number of expansion boards (SB, CB
BB)1
Hardware configuration — number of signal modules (SM)6
Hardware configuration — number of communications modules (CM)3
Backup time480 h; Typical
Deviation per day, max.2 s; at 25 °C
Number of digital inputs8; Integrated
Digital inputs — of which inputs usable for technological functions8; HSC (High Speed Counting)
Input voltage — Rated value (DC)24 V
Input voltage — for signal "0"5 V DC or 0.5 mA
Input voltage — for signal "1"15 V DC at 2.5 mA
Input delay for technological functionssingle phase: 6 HSCs @ 100 kHz & 2 standard @ 30 kHz, quadrature phase: 6 HSCs @ 80 kHz & 2 standard @ 20 kHz
Cable length — shielded, max.500 m
Cable length — unshielded, max.300 m
Number of digital outputs6; 20 kHz or 100 kHz
Digital outputs — of which high-speed outputs4; 100 kHz (Qa.0 - Qa.3)
Switching capacity of the outputs — with resistive load, max.0.5 A
Switching capacity of the outputs — on lamp load, max.5 W
Output voltage for signal "1", min.20 V
Output current for signal "1" rated value0.5 A
Switching frequency of the pulse outputs, with resistive load, max.100 kHz
Relay outputs0
Number of analog inputs0
Traces — Memory size per trace, max.512 kbyte
Counting frequency, max.100 kHz; Ia.0 to Ia.5: 100 kHz (80 kHz in quadrature mode)
Ia.6 to Ia.730 kHz
Limit frequency (pulse)100 kHz
Potential separation digital inputsYes; field side to logic: 707 V DC (type test)
Ambient temperature during operation — horizontal installation, max.60 °C
Ambient temperature during operation — vertical installation, max.50 °C
Ambient temperature during operation — min.-20 °C; No condensation
Ambient temperature during storage/transportation — min.-40 °C
Ambient temperature during storage/transportation — max.70 °C
Installation altitude, max.5 000 m
Relative humidity Operation, max.95 %; no condensation
Dimensions — Width70 mm
Dimensions — Height125 mm
Dimensions — Depth100 mm
Weight, approx.319 g
Width70 mm
ModelCompact
Height125 mm
Depth100 mm
With displayNo
Suitable for safety functionsNo
Voltage type (supply voltage)DC
Memory size650 kByte
Processing time (1K, binary operation)37 ms
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet1
With optical interfaceNo
Additional program memory possibleNo
Supporting protocol for TCP/IPYes
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
RedundancyYes
Suitable for rail mountingYes
Explosion safety category for gasATEX gas-ex-protection, Cat. 3G
Explosion safety category for dustNone
System accessoryYes
Appendant operation agent (Ex ia)No
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Number of interfaces PROFINET1
Front built-in possibleNo
Rack-assembly possibleNo
Wall mounting/direct mountingYes
Radio standard BluetoothNo
Radio standard WLAN 802.11No
IO link masterNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IOYes
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supply voltage DC20.4–28.8 V
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
Mobile communications standard 4G (LTE)No
Supporting protocol for EtherCATNo
Country of originChina