| Manufacturer part number (MPN) | 3SU1400-2AA10-1BA0 |
| EAN / GTIN | 4011209950917 |
| Sales unit | pcs |
| Package quantity | 5 pcs |
| Product type designation | 3SU1 |
| Insulation voltage rated value | 500 V |
| Degree of pollution | 3 |
| Type of voltage — of the operating voltage | AC/DC |
| Type of voltage — of the input voltage | AC/DC |
| Surge voltage resistance rated value | 6 kV |
| Protection class IP — of the enclosure | IP40 |
| Protection class IP — of the terminal | IP20 |
| Shock resistance — according to IEC 60068-2-27 | sinusoidal half-wave 15 g / 11 ms |
| Shock resistance — for railway applications according to EN 61373 | Category 1, Class B |
| Vibration resistance — according to IEC 60068-2-6 | 10 ... 500 Hz: 5 g |
| Vibration resistance — for railway applications according to EN 61373 | Category 1, Class B |
| Operating frequency maximum | 3 600 1/h |
| Mechanical service life (operating cycles) typical | 10 000 000 |
| Electrical endurance (operating cycles) typical | 10 000 000 |
| Thermal current | 10 A |
| Continuous current of the C characteristic MCB | 10 A |
| General technical data — Net Weight | 8.3 g |
| At AC — at 50 Hz rated value | 5 ... 500 V |
| At AC — at 60 Hz rated value | 5 ... 500 V |
| At AC — at DC rated value | 5 ... 500 V |
| Contact reliability | One maloperation per 100 million (17 V, 5 mA), one maloperation per 10 million (5 V, 1 mA) |
| Number of NC contacts for auxiliary contacts | 0 |
| Number of NC contacts for auxiliary contacts — lagging switching | 0 |
| Number of NO contacts for auxiliary contacts | 1 |
| Number of NO contacts for auxiliary contacts — leading contact | 0 |
| Operational current at AC-12 — at 24 V rated value | 10 A |
| Operational current at AC-12 — at 48 V rated value | 10 A |
| Operational current at AC-12 — at 110 V rated value | 10 A |
| Operational current at AC-12 — at 230 V rated value | 8 A |
| Operational current at AC-12 — at 400 V rated value | 8 A |
| Operational current at AC-15 — at 24 V rated value | 6 A |
| Operational current at AC-15 — at 48 V rated value | 6 A |
| Operational current at AC-15 — at 110 V rated value | 6 A |
| Operational current at AC-15 — at 230 V rated value | 6 A |
| Operational current at AC-15 — at 400 V rated value | 3 A |
| Operational current at AC-15 — at 500 V rated value | 1.4 A |
| Operational current at DC-12 — at 24 V rated value | 10 A |
| Operational current at DC-12 — at 48 V rated value | 5 A |
| Operational current at DC-12 — at 110 V rated value | 2.5 A |
| Operational current at DC-12 — at 230 V rated value | 1 A |
| Operational current at DC-12 — at 400 V rated value | 0.3 A |
| Operational current at DC-12 — at 500 V rated value | 0.3 A |
| Operational current at DC-13 — at 24 V rated value | 3 A |
| Operational current at DC-13 — at 48 V rated value | 1.5 A |
| Operational current at DC-13 — at 110 V rated value | 0.7 A |
| Operational current at DC-13 — at 230 V rated value | 0.3 A |
| Operational current at DC-13 — at 400 V rated value | 0.1 A |
| Operational current at DC-13 — at 500 V rated value | 0.1 A |
| Type of connectable conductor cross-sections — solid with core end processing | 2x (0.5 ... 0.75 mm²) |
| Type of connectable conductor cross-sections — solid without core end processing | 2x (1.0 ... 1.5 mm²) |
| Type of connectable conductor cross-sections — finely stranded with core end processing | 2x (0.5 ... 1.5 mm²) |
| Type of connectable conductor cross-sections — finely stranded without core end processing | 2x (1,0 ... 1,5 mm²) |
| Type of connectable conductor cross-sections — for AWG cables | 2x (18 ... 14) |
| Tightening torque with screw-type terminals | 0.8 ... 0.9 N·m |
| Ambient temperature — during operation | -25 ... +70 °C |
| Ambient temperature — during storage | -40 ... +80 °C |
| Installation/ mounting/ dimensions — height | 33.2 mm |
| Installation/ mounting/ dimensions — width | 9.8 mm |
| Installation/ mounting/ dimensions — depth | 27.7 mm |
| Country of origin | Germany |